P 5 / 11
R
epair
[3] DISASSEMBLY/ASSEMBLY
[3] -2. Armature
ASSEMBLING
DISASSEMBLING
(5) Separate Armature from Bracket complete, and remove Ball bearings as shown in
Fig. 7
.
Bracket complete
Bracket complete
Ball bearing
606ZZ
Ball bearing
606ZZ
Insulation washer
Insulation washer
1R045
Claw
Armature
Armature
Insulation
washer
1. Firmly gripping Bracket complete with 1R045, separate Armature from Bracket complete.
Drum
V pulley 4-20L
Fig. 7
Fig. 8
2. The gap between Insulation washer and
Ball bearing 606ZZ is too tight to engage
claw of 1R269. So, fixing claw of 1R269
with Water pump pliers firmly,
remove Ball bearing 606ZZ.
Ball bearing 606ZZ
Water pump pliers
1R269
Claw
Ball bearing 6000ZZ
Assembling can be made by taking reverse step of Disassembling. Refer to
Fig. 7
,
Fig. 6
,
Fig. 5
,
Fig. 4.
3. Remove Ball bearing 6000ZZ with 1R269.
Turn counter
clockwise
for
tightening
.
12
3
6
9
V pulley 4-20L
Bracket complete
< Note >
Enough to tighten V pulley 4-20L
to proper level in this step.
V pulley 4-20L is tightened
automatically to firm level
by rotation of Armature.
Armature
Pay attention to
Fig. 8
, when assembling V pulley 4-20L.
Grip Drum with groved hand,
to protect hand against injury.