P 8/ 35
R
epair
13) To remove Motor section from Blade case section, remove Carbon brushes first.
14) Regarding LS1216L only, remove Lead cover holder and 4x18 Tapping screw then disconnect Connectors for Laser
circuit. (
Fig. 14
)
16) Remove four M6x80 Pan head screws using Cordless impact driver with Phillips bit No.3.
Motor section, Motor bracket and Handle section can be removed from Blade case section. (
Fig. 15
)
Handle cover can be removed by loosening six 4x18 Tapping screws.
Take the disassembling step in reverse. Be sure to apply grease to the specific portions in advance. (
Fig. 3
)
Note
: File off any burrs on Rod 16.
When Rod 16 is assembled to Blade case complete;
1. Move Blade case complete to the lowest position and lock it by pushing Knob 20, then insert the end of
Rod 16 to inner surface of Blade case complete. (
Fig. 16
)
2. Pull Knob 20 to unlock Blade case complete then stand Blade case complete vertically and lock it by pushing
Knob 20. (
Fig. 17
)
3. Assemble Sleeve 17 to Torsion spring 40 (
Fig. 17
) and put one end of Torsion spring 40 into the groove of
Front arm complete.
4. Insert the assembled parts into Blade case complete, then install the end of Rod 16 to the outer surface of Front
arm complete through Sleeve 17. (
Fig. 18
)
DISASSEMBLING
Fig. 15
ASSEMBLING
[3] DISASSEMBLY/ASSEMBLY
[3]-1. Blade case section, Motor section (cont.)
Fig. 14
Fig. 17
Fig. 16
Fig. 18
Lead cover holder
Connectors
for Laser circuit
Handle section
Blade case
section
4x18 Tapping screw
Motor
section
M6x80 Pan head screw (4pcs.)
Motor section
Knob 20
End of
Rod 16
Sleeve 17
Outer surface of Front arm complete
End of Rod 16
Knob 20
Front arm complete
Torsion
spring 40
Blade case complete stands vertical to Turn base
Front arm complete
Blade case complete at
the lowest position
Handle section
(Top: Handle cover)
(Bottom: Handle complete)
Motor bracket
One end of Torsion spring 40
Inner surface of
Blade case complete
Groove of
Front arm complete
782223-9 or less than
ø
16mm rod