![Makita HR4501C Technical Information Download Page 19](http://html1.mh-extra.com/html/makita/hr4501c/hr4501c_technical-information_4190583019.webp)
P
19
/ 2
3
[3] DISASSEMBLY/ASSEMBLY
[3] -10. Handle Section (HR4511C: with Vibration absorbing handle)
R
epair
ASSEMBLY
Facing the bow portion of Dust cover
to the upper side of the machine,
assemble Dust cover to Handle.
Dust cover support
Handle
Handle base
Do the reverse step of Disassembly. Refer to
Figs. 60 to 58
.
Refer to
Fig. 62
when assembling Dust cover and Dust cover support to Handle.
Facing Triangle mark to the
upper side, insert Dust cover
support into Dust cover.
Upper side
Lower side
Dust cover
5x40 Tapping
screw (2 pcs.)
Flat washer 5
Fig. 62
Fig. 60
Fig. 61
Fig. 59
Shoulder
sleeve 19
5x25 Tapping screw
5x40 Tapping screw (2 pcs.)
Flat washer 5
Handle
Handle base
Dust cover support
Dust cover
Handle cover
Separate Handle section from the machine
by unscrewing 5x25 Tapping screws.
Remove another two
5x25 Tapping screws
to disassemble Handle
in the next step.
Remove 5x40 Tapping screws.
The several parts are separated from
Handle base as illlutrated above.
Handle cover can be removed
as the left Illustration in
Fig. 46
.
Compression spring 11
Spring guide
Crank cap cover
After removing Crank cap cover, Spring
guide with Compression spring 11 can be
removed from Crank housing complete.
5x25 Tapping
screw (6 pcs.)
DISASSEMBLY
1) Vibration absorbing handle consists of the following main parts.
* Handle base * Dust cover and Dust cover support
* Compression spring 11 (functions as a Vibration absorber) * Handle with Handle cover
2) Disassemble in the order from
Figs. 59 to Fig. 61
when replacing the electrical parts in Handle section.