background image

6 ENGLISH

FUNCTIONAL DESCRIPTION

CAUTION:

 

Always be sure that the tool is 

switched off and the battery cartridge is removed 

before adjusting or checking function on the tool.

Installing or removing battery cartridge

CAUTION:

 

Always switch off the tool before 

installing or removing of the battery cartridge.

CAUTION:

 

Hold the tool and the battery cartridge 

firmly when installing or removing battery cartridge.

 

Failure to hold the tool and the battery cartridge firmly may 

cause them to slip off your hands and result in damage to 

the tool and battery cartridge and a personal injury.

1

2

3

►    

1.

 Red indicator 

2.

 Button 

3.

 Battery cartridge

To remove the battery cartridge, slide it from the tool 

while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the 

battery cartridge with the groove in the housing and slip 

it into place. Insert it all the way until it locks in place 

with a little click. If you can see the red indicator on the 

upper side of the button, it is not locked completely.

CAUTION:

 

Always install the battery cartridge 

fully until the red indicator cannot be seen.

 If not, 

it may accidentally fall out of the tool, causing injury to 

you or someone around you.

CAUTION:

 

Do not install the battery cartridge 

forcibly.

 If the cartridge does not slide in easily, it is 

not being inserted correctly.

Battery protection system

The battery cartridge is equipped with the protection system, which 

automatically cuts off the output power for its long service life.

The tool stops during operation when the tool and/or battery are 

placed under the following situation. This is caused by the acti-

vation of protection system and does not show the tool trouble.
• 

When the tool/battery is overloaded:

At this time, release the switch trigger, remove the 

battery cartridge and remove causes of overload 

and then pull the switch trigger again to restart.

• 

When battery cells get hot:

If any operation of the switch trigger, the motor will 

remain stopped. At this time, stop use of the tool 

and cool the battery cartridge.

• 

When the remaining battery capacity gets low:

If you pull the switch trigger, the motor runs again 

but stops soon. In this case, to prevent over dis-

charge, remove the battery cartridge from the tool 

and charge it.

Switch action

1

►    

1.

 Switch trigger

CAUTION:

 

Before installing the battery car-

tridge into the tool, always check to see that the 

switch trigger actuates properly and returns to 

the "OFF" position when released.

To start the tool, simply pull the switch trigger. Tool 

speed is increased by increasing pressure on the switch 

trigger. Release the switch trigger to stop.

Reversing switch action

1

A

B

►    

1.

 Reversing switch lever

CAUTION:

 

Always check the direction of 

rotation before operation.

CAUTION:

 

Use the reversing switch only after 

the tool comes to a complete stop.

 Changing the direc-

tion of rotation before the tool stops may damage the tool.

CAUTION:

 

When not operating the tool, always 

set the reversing switch lever to the neutral position.

This tool has a reversing switch to change the direction 

of rotation. Depress the reversing switch lever from the 

A side for clockwise rotation or from the B side for coun-

terclockwise rotation.

When the reversing switch lever is in the neutral posi-

tion, the switch trigger cannot be pulled.

Summary of Contents for HP488DWE

Page 1: ...INSTRUCTION MANUAL Cordless Hammer Driver Drill HP488D ENGLISH Original instructions Read before use...

Page 2: ...Batteries and Accumulators and their implementation in accordance with national laws electric equipment and batteries and battery pack s that have reached the end of their life must be col lected sep...

Page 3: ...f your body is earthed or grounded 3 Do not expose power tools to rain or wet con ditions Water entering a power tool will increase the risk of electric shock 4 Do not abuse the cord Never use the cor...

Page 4: ...at is suitable for one type of battery pack may create a risk of fire when used with another battery pack 2 Use power tools only with specifically desig nated battery packs Use of any other battery pa...

Page 5: ...or hit against a hard object to the battery cartridge Such conduct may result in a fire excessive heat or explosion 9 Do not use a damaged battery 10 The contained lithium ion batteries are subject to...

Page 6: ...hen the tool and or battery are placed under the following situation This is caused by the acti vation of protection system and does not show the tool trouble When the tool battery is overloaded At th...

Page 7: ...modes Drilling mode rotation only Hammer drilling mode rotation with hammering Screwdriving mode rotation with clutch Select one mode suitable for your work Turn the action mode changing ring and alig...

Page 8: ...not force the tool Light pressure gives best results Keep the tool in position and prevent it from slipping away from the hole Do not apply more pressure when the hole becomes clogged with chips or p...

Page 9: ...ement parts OPTIONAL ACCESSORIES CAUTION These accessories or attachments are recommended for use with your Makita tool specified in this manual The use of any other accessories or attachments might p...

Page 10: ...10...

Page 11: ...11...

Page 12: ...www makita com Makita Europe N V Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan Jan Baptist Vinkstraat 2 3070 Kortenberg Belgium 885837 220 EN 20200831...