9 ENGLISH
Overheat protection
When the tool/battery is overheated, the tool stops
automatically. Let the tool cool down before turning the
tool on again.
Overdischarge protection
When the battery capacity is not enough, the tool stops
automatically. In this case, remove the battery from the
tool and charge the battery.
Releasing protection lock
When the protection system works repeatedly, the tool
is locked.
In this situation, the tool does not start even if turning
the tool off and on. To release the protection lock,
remove the battery, set it to the battery charger and wait
until the charging finishes.
Protections against other causes
Protection system is also designed for other causes
that could damage the tool and allows the tool to stop
automatically. Take all the following steps to clear the
causes, when the tool has been brought to a temporary
halt or stop in operation.
1. Turn the tool off, and then turn it on again to
restart.
2. Charge the battery(ies) or replace it/them with
recharged battery(ies).
3. Let the tool and battery(ies) cool down.
If no improvement can be found by restoring protection
system, then contact your local Makita Service Center.
Shaft lock
WARNING:
Never actuate the shaft lock when
the spindle is moving.
It may cause serious injury or
the tool damage.
Press the shaft lock to prevent spindle rotation when
installing or removing accessories.
1
Fig.3
►
1.
Shaft lock
Switch action
CAUTION:
Before installing the battery car-
tridge into the tool, always check to see that the
switch lever actuates properly and returns to the
"OFF" position when released.
CAUTION:
For your safety, this tool is
equipped with lock-off lever which prevents the
tool from unintended starting. NEVER use the tool
if it runs when you simply pull the switch lever
without pulling the lock-off lever. Return the tool
to our authorized service center for proper repairs
BEFORE further usage.
CAUTION:
Do not pull the switch lever hard
without pulling the lock-off lever.
This can cause
switch breakage.
CAUTION:
NEVER tape down or defeat pur-
pose and function of lock-off lever.
1
2
Fig.4
►
1.
Lock-off lever
2.
Switch lever
To prevent the switch lever from being accidentally
pulled, a lock-off lever is provided.
To start the tool, pull the lock-off lever toward the opera
-
tor and then pull the switch lever.
To stop the tool, release the switch lever.
Accidental re-start preventive
function
When installing the battery cartridge while the switch is
ON, the tool does not start.
To start the tool, turn off the switch, and turn it on again.
Active Feedback sensing
Technology
The tool electronically detects situations where the
wheel or accessory may be at risk to be bound. In the
situation, the tool is automatically shut off to prevent
further rotation of the spindle (it does not prevent
kickback).
To restart the tool, switch off the tool first, remove the
cause of sudden drop in the rotation speed, and then
turn the tool on.