[3] DISASSEMBLY/ASSEMBLY

[3] -1. Gear section (Gear 12-31,  Helical gear 47)

ASSEMBLING

Fig. 3

Fig. 4

Fig. 5

(1) Assemble Helical gear 47, Gear 12-31. (

Figs. 3, 4

)  And mount them to Housing L. (

Fig. 5

(2) Assemble Protector to housing set. (

Center right

 in 

Fig. 2)

(3) Mount Crank complete. Refer to the

 center right

 drawing in 

Fig. 2

.

(4) Mount Shear blade assembly and Under cover.  Refer to 

Fig. 6

.

Crank side of Helical gear 47

1. Face the crank side of Helical

gear 47 to the bottom.

2. Pressfit 2pcs. of Pin 4 to

Helical gear 47.

3. Facing the notch side of Pin 6 to top, pass it

through Washer 6 into Helical gear 47.

long pin 6

5. Assemble Helical gear 47

with fitting the notch of Pin 6

on the Rib of Housing L.

Notch of Pin 6

Helical gear 47

DC motor

Rib

Washer 6

Housing L

Notch

Pin 6

Pin 4

4. Pass Pin 6 through Gear 12-31

and two Washers 6 as drawn below,

then set them in place in Housing L.

Pin 6

Washer 6

Washer 6

Gear 12-31

Fig. 6

Shear blade A

Hole of Shear

blade A   Hole of Shear

blade B 

2. Align the elliptical hole

of Shear blade A with

that of Shear blade B.

Shear blade B

3. Set Shear blade assembly

in place.

Note: Crank portions of 

          Shear blades A and 

          B have to be fit into 

          Crank complete 

          correctly.

Joint of Housing L

and Housing R

1. Turn Crank complete until

the projections come to the

following position.

4. Put Under cover complete on the bottom of

Housing set as drawn below.

5. Turn Under cover complete toward the locking position

with Lock lever pressed as drawn below.

Crank complete 

Lock lever

Under cover

complete

Unlocked position

Locking position

Crank portions of 

Shear blades 

Summary of Contents for DUM166

Page 1: ...ng two M4 thumb nuts Blade cover set 9 4 including Blade cover for hedge trimmer shear blade Storage case for grass shear blade For DUM166 Battery BL1415 Battery BL1430 Battery BL1815 Battery BL1820 F...

Page 2: ...es 2 LUBRICATION Fig 1 Item No Description Crank Helical gear 47 Housing L Gear 12 31 Gear teeth with which Helical gear 47 and DC motor gear engage Drum portion where Blade contacts 17 Pin 6 with a n...

Page 3: ...complete and Shear blade assembly Shear blade assembly Under cover complete Dust guard M4x12 Bind head screw Protector Crank complete 5 Remove Protector by unscrewing M4x12 Bind head screw 4 Remove Cr...

Page 4: ...L Notch of Pin 6 Helical gear 47 DC motor Rib Washer 6 Housing L Notch Pin 6 Pin 4 4 Pass Pin 6 through Gear 12 31 and two Washers 6 as drawn below then set them in place in Housing L Pin 6 Washer 6 W...

Page 5: ...And mount them to Housing L Fig 5 2 Mount DC motor to Housing L as drawn in Fig 8 Hex bolt Set DC motor in place fitting the head of Hex bolt on DC motor to the groove of Housing L Groove DC motor Ho...

Page 6: ...g 9 3 Mount Shear blade assembly option for hedge trimmer on Crank housing Fig 10 1 Turn Crank complete until the projections come to the following position Joint of Housing L and Housing R 2 Slide th...

Page 7: ...Fig D 1 Color index of lead wires sheath Black Red Yellow White LED circuit Warning lamp DUM166 DUM168 P 7 9 Circuit diagram Controller Terminal Heat shrink tube...

Page 8: ...ng portion of Receptacles Lead wire red 3 DC motor can be mounted with the wire connecting portions of Receptacles faced to Housing L side Housing L Red dot marking Ribs Adhesive for Connecting lead w...

Page 9: ...ad wire holder Wiring in Housing L See Fig D 3 for the wiring of LED warning lamp See Figs D 1 and D 2 for the wiring of Terminal See Fig D 5 for the wiring of Controller P 9 9 Wiring diagram cont See...