P
5
/ 1
2
R
epair
DISASSEMBLING
ASSEMBLING
(4) Remove Bearing retainer and Ball bearing 627DDW as drawn in
Fig. 5
.
(1) Assemble Ball bearing 627DDW to the commutator end of Armature. (Refer to
Fig. 5
.)
(2) Assemble the component parts to the drive end of Armature by reversing the disassembly procedure.
(Refer to
Figs. 5
and
4
.)
(3) Assemble the Armature section to Crank housing complete as drawn in
Fig. 6
.
Note
: For easy assembling of Armature section, heat Crank housing complete with a heat gun after setting Connector
as drawn in
Fig. 7
.
2. By using with 1R269, Remove Ball bearing 627DDW
from the commutator end of Armature.
1. Remove Bearing retainer
from the drive end of Armature.
Fig. 5
Bearing
retainer
Ball bearing
627DDW
2. Heat Crank housing complete
with a heat gun.
Armature section
Crank housing
complete
Fig. 6
Fig. 7
1. Set Connector to the center.
Projection of
Motor housing
Notch of
Yoke unit
Switch lever side
(4) If Yoke unit is disassembled or replaced, re-assemble Yoke unit as drawn in
Fig. 7
.
Handle cover
complete side
Fitting the notch of Yoke unit to
the projection of Motor housing,
assemble Yoke unit to Motor housing.
[3] DISASSEMBLY/ASSEMBLY
[3] -1. Armature (cont.)