State of abnormality
Probable cause (malfunction)
Remedy
The vacuum cleaner does not run
along with the switch operation of
the tool.
The wireless unit is not installed into
the tool.
The wireless unit is improperly installed
into the tool.
Install the wireless unit correctly.
The terminal of the wireless unit and/or
the slot is dirty.
Gently wipe off dust and dirt on the terminal of the
wireless unit and clean the slot.
The wireless activation button on the
tool has not been pushed.
Push the wireless activation button briefly and make
sure that the wireless activation lamp is blinking
in blue.
The stand-by switch on the vacuum
cleaner is not set to "AUTO".
Set the stand-by switch on the vacuum cleaner to
"AUTO".
More than 10 tools are registered to the
vacuum cleaner.
Perform the tool registration again.
If more than 10 tools are registered to the vacuum
cleaner, the tool registered earliest will be cancelled
automatically.
The vacuum cleaner erased all tool
registrations.
Perform the tool registration again.
No power supply
Supply the power to the tool and the vacuum
cleaner.
The tool and vacuum cleaner is away
from each other (out of the transmission
range).
Get the tool and vacuum cleaner closer each other.
The maximum transmission distance is approxi
-
mately 10 m however it may vary according to the
circumstances.
Radio disturbance by other appliances
which generate high-intensity radio
waves.
Keep the tool and vacuum cleaner away from the
appliances such as Wi-Fi devices and microwave
ovens.
The vacuum cleaner runs while the
tool's switch trigger is not pulled.
Other users are using the wireless
activation of the vacuum cleaner with
their tools.
Turn off the wireless activation button of the other
tools or cancel the tool registration of the other
tools.
MAINTENANCE
WARNING:
Always be sure that the tool is
switched off and batteries are removed before
attempting to perform inspection or maintenance.
Failure to removing the batteries and switch off the
tool may result in accidental start up of the tool which
may result in serious personal injury.
WARNING:
Always be sure that the blade is
sharp and clean for the best and safest perfor-
mance.
Attempting a cut with a dull and /or dirty blade
may cause kickback and result in a serious personal
injury.
NOTICE:
Never use gasoline, benzine, thinner,
alcohol or the like. Discoloration, deformation or
cracks may result.
Adjusting the cutting angle
This tool is carefully adjusted and aligned at the factory,
but rough handling may have affected the alignment. If
your tool is not aligned properly, perform the following:
Miter angle
Lower the handle fully and lock it in the lowered position
by the stopper pin. Push the carriage toward the guide
fence. Loosen the grip and the screws which secure the
pointer and miter angle scale.
►
Fig.70:
1.
Screw on pointer
2.
Screws on miter
angle scale
3.
Miter scale
Set the turn base to the 0° position using the positive
stop function. Square the side of the blade with the face
of the guide fence using a triangular rule or try-square.
While keeping the square, tighten the screws on the
miter angle scale. After that, align the pointers (both
right and left) with the 0° position in the miter angle
scale and then tighten the screw on the pointer.
►
Fig.71:
1.
Triangular rule
Bevel angle
0° bevel angle
Push the carriage toward the guide fence and lock the
sliding movement by the stopper pin. Lower the handle
fully and lock it in the lowered position by the stopper
pin and then loosen the knob. Turn the 0° adjusting
bolt two or three revolutions counterclockwise to tilt the
blade to the right.
►
Fig.72:
1.
0° Adjusting bolt
2.
Screw
Carefully square the side of the blade with the top
surface of the turn base using the triangular rule, try-
square, etc. by turning the 0° adjusting bolt clockwise.
Then tighten the knob firmly to secure the 0° angle you
have set.
►
Fig.73:
1.
Triangular rule
2.
Saw blade
3.
Top sur
-
face of turn base
Check if the side of the blade squares with the turn base
surface once again. Loosen the screw on the pointer.
Align the pointer with 0° position in the bevel angle
scale and then tighten the screw.
Summary of Contents for DLS111
Page 2: ...Fig 1 10 11 12 14 15 3 2 4 5 8 7 9 13 6 1 16 17 18 20 21 22 19 Fig 2 2 ...
Page 3: ...16 17 20 19 18 21 15 1 2 3 11 13 14 12 4 6 6 7 8 5 9 10 Fig 3 1 2 Fig 4 1 2 4 4 3 Fig 5 3 ...
Page 4: ...2 1 3 Fig 6 1 Fig 7 1 2 3 Fig 8 2 1 1 Fig 9 1 2 Fig 10 1 Fig 11 1 Fig 12 4 ...
Page 5: ...3 1 2 Fig 13 1 Fig 14 1 2 3 4 6 5 Fig 15 1 Fig 16 1 Fig 17 1 2 3 Fig 18 5 ...
Page 6: ...1 2 Fig 19 1 2 3 4 Fig 20 1 Fig 21 1 Fig 22 1 2 Fig 23 1 Fig 24 6 ...
Page 7: ...1 Fig 25 1 Fig 26 1 2 3 Fig 27 1 2 3 Fig 28 1 Fig 29 1 Fig 30 A B Fig 31 1 Fig 32 7 ...
Page 8: ...2 1 3 Fig 33 3 1 2 Fig 34 1 2 5 3 4 Fig 35 1 2 Fig 36 1 2 3 4 5 6 Fig 37 8 ...
Page 9: ...1 2 3 1 2 3 Fig 38 1 2 Fig 39 1 Fig 40 1 2 Fig 41 1 2 3 1 2 3 4 4 Fig 42 1 2 3 Fig 43 9 ...
Page 10: ...1 2 3 4 Fig 44 1 2 3 Fig 45 1 2 Fig 46 1 Fig 47 1 Fig 48 10 ...
Page 12: ...1 Fig 56 Fig 57 Fig 58 1 Fig 59 1 4 2 3 Fig 60 1 2 3 Fig 61 1 Fig 62 12 ...
Page 13: ...1 2 1 2 Fig 63 Fig 64 1 Fig 65 1 2 Fig 66 1 Fig 67 1 Fig 68 13 ...
Page 14: ...1 2 1 2 Fig 69 2 1 2 3 Fig 70 1 Fig 71 1 2 Fig 72 1 2 3 Fig 73 Fig 74 14 ...
Page 15: ...1 2 Fig 75 4 5 1 2 3 Fig 76 4 5 1 2 3 Fig 77 1 2 Fig 78 15 ...