P
9
/1
4
R
epair
[3] DISASSEMBLY/ASSEMBLY
[3]-3. Motor Section (Armature, Yoke unit, Brush holder)
ASSEMBLING
Fig. 14
1) Assemble Motor section as described in
Fig. 14
.
1. Insert Armature into Yoke unit
in the direction of the arrow.
2. Mount Brush holder complete
to Armature.
notch
Note:
The notch on Yoke unit must be
positioned on the Armature fan side.
notch
Brush holder
complete
Yoke unit
3. Assemble Motor section to Housing (L) complete by engaging the notch of Yoke unit
to the protrusion of Housing (L) complete. Then make sure that Yoke unit and
Brush holder complete are exactly mounted to Housing (L) complete. (
Fig. 14A, 14B)
notch
Yoke unit
Yoke unit must be
exactly set between
these ribs.
protrusion
Housing (L) complete
Terminal
Yoke unit
The flat portion of Brush holder complete must be at right angle
vertically as shown below when it is mounted to Housing (L)
complete.
Brush holder
complete
Housing (L)
complete
flat portion of
Brush holder complete
90 degrees
Fig. 14A
Fig. 14B
Note:
Carefully insert Armature to Yoke unit
so as not to damage magent wire
or pinch your finger because Armature
will be pulled towards Yoke unit with
strong magnetic force of Yoke unit.