background image

6

ENGLISH

Air duster

CAUTION:

 

Do not aim the ejection port of the 

air duster to someone. Also, keep your hands and 
foot away from the ejection port.

 If the air duster 

button is accidentally pushed, it may cause a per

-

sonal injury.

CAUTION:

 

Always check your surroundings 

before using the air duster.

 Blown dust or objects 

may hit someone.

CAUTION:

 

Do not connect or disconnect the 

air hose while pushing the air duster button.

The air supplied to the tool can also be used as an air 

duster. You can clean the work area by pressing the 
button on the grip end.

1

    

1.

 Button

NOTICE:

 After using the air duster, the driving force 

of the tool will temporarily decline. Wait until the air 
pressure recovers in this case.

NOTICE:

 Perform a test blow if you use the air 

duster immediately after the oil was applied. The oil 

may be sprayed with the air.

ASSEMBLY

CAUTION:

 

Before carrying out any work on 

the tool, always return the trigger and disconnect 
the air hose from the tool.

CAUTION:

 

Load the same type, size and 

uniform length of staples when loading multiple 
strips of staples in the magazine.

Loading stapler

NOTE:

 Always hold the rear of the sliding door when 

you press the lever. The sliding door opens suddenly 

with the lever pressed when staples are stored in the 

magazine.

1.

 

Press the lever and open the sliding door of the 

magazine.

1

2

    

1.

 Lever 

2.

 Sliding door

2.

 

Insert a strip of staples into the opening of the 

magazine all the way.

3.

 

Close the sliding door until the sliding door is 

locked.

Removing staples

To remove staples, follow the procedures of “Loading 

stapler” in reverse.

Nose adapter

To prevent the surface of workpiece from being 

scratched or damaged, use the nose adapter.

Summary of Contents for AT638A

Page 1: ...INSTRUCTION MANUAL Narrow Crown Stapler AT638A ENGLISH Original instructions Read before use...

Page 2: ...y Respect the tool as a working implement 3 Do not operate when under the inluence of alcohol drugs or the like 4 Never alter the tool Personal protective equipments 1 Always wear safety glasses to pr...

Page 3: ...ore operation Tighten as required 2 Handle the tool carefully as there is high pres sure inside the tool that can be dangerous if a crack is caused by rough handling dropping or striking Do not attemp...

Page 4: ...se adapter contact element 3 Hook 4 Magazine INSTALLATION Selecting compressor 10 20 30 40 50 60 20 30 40 50 60 10 2 1 3 4 5 1 Stapling frequency times min 2 Compressor air output per minute L min 3 0...

Page 5: ...ced 1 1 Pneumatic tool oil FUNCTIONAL DESCRIPTION CAUTION Before adjusting or checking function on the tool always return the trigger and disconnect the air hose from the tool Adjusting depth of stapl...

Page 6: ...u use the air duster immediately after the oil was applied The oil may be sprayed with the air ASSEMBLY CAUTION Before carrying out any work on the tool always return the trigger and disconnect the ai...

Page 7: ...operation Selecting the operation mode CAUTION Always make sure that the actua tion mode selector is properly set to the position for the desired stapling mode before stapling 1 1 Actuation mode sele...

Page 8: ...and remove jammed staples from the staple rail MAINTENANCE CAUTION Before attempting to perform inspection or maintenance always return the trig ger and disconnect the air hose from the tool NOTICE N...

Page 9: ...e To maintain product SAFETY and RELIABILITY repairs any other maintenance or adjustment should be performed by Makita Authorized or Factory Service Centers always using Makita replacement parts OPTIO...

Page 10: ...10...

Page 11: ...11...

Page 12: ...Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan www makita com AT638A ENAU 1604 EN 20160624...

Reviews: