1.

 Nose adapter 

2.

 Contact element

A spare nose adapter is stored in the place shown in 

the igure.

1

    

1.

 Spare nose adapter

Connecting air hose

1

2

    

1.

 Air itting 

2.

 Air socket

Slip the air socket of the air hose onto the air itting on 

the stapler. Be sure that the air socket locks irmly into 

position when installed onto the air itting. 

 

A hose coupling must be installed on or near the tool in 
such a way that the pressure reservoir will discharge at 
the time the air supply coupling is disconnected.

OPERATION

CAUTION:

 

Make sure all safety systems are in 

working order before operation.

Selecting the operation mode

CAUTION:

 

Always make sure that the actua-

tion mode selector is properly set to the position 
for the desired stapling mode before stapling.

1

    

1.

 Actuation mode selector

Single sequential actuation mode:

You can drive one staple by one sequential operation. 
Select this mode when driving a staple carefully and 
accurately.

To choose this mode, set the actuation mode selector to 

the 

 position.

Contact actuation mode:

You can drive staples repetitively by placing the contact 
element with the trigger held.

To choose this mode, set the actuation mode selector to 

the 

 position.

Single sequential actuation

Place the contact element against the workpiece and 
pull the trigger fully.

After stapling, release the contact element, and then 

release the trigger.

2

1

Summary of Contents for AT638A

Page 1: ...INSTRUCTION MANUAL Narrow Crown Stapler AT638A ENGLISH Original instructions Read before use...

Page 2: ...y Respect the tool as a working implement 3 Do not operate when under the inluence of alcohol drugs or the like 4 Never alter the tool Personal protective equipments 1 Always wear safety glasses to pr...

Page 3: ...ore operation Tighten as required 2 Handle the tool carefully as there is high pres sure inside the tool that can be dangerous if a crack is caused by rough handling dropping or striking Do not attemp...

Page 4: ...se adapter contact element 3 Hook 4 Magazine INSTALLATION Selecting compressor 10 20 30 40 50 60 20 30 40 50 60 10 2 1 3 4 5 1 Stapling frequency times min 2 Compressor air output per minute L min 3 0...

Page 5: ...ced 1 1 Pneumatic tool oil FUNCTIONAL DESCRIPTION CAUTION Before adjusting or checking function on the tool always return the trigger and disconnect the air hose from the tool Adjusting depth of stapl...

Page 6: ...u use the air duster immediately after the oil was applied The oil may be sprayed with the air ASSEMBLY CAUTION Before carrying out any work on the tool always return the trigger and disconnect the ai...

Page 7: ...operation Selecting the operation mode CAUTION Always make sure that the actua tion mode selector is properly set to the position for the desired stapling mode before stapling 1 1 Actuation mode sele...

Page 8: ...and remove jammed staples from the staple rail MAINTENANCE CAUTION Before attempting to perform inspection or maintenance always return the trig ger and disconnect the air hose from the tool NOTICE N...

Page 9: ...e To maintain product SAFETY and RELIABILITY repairs any other maintenance or adjustment should be performed by Makita Authorized or Factory Service Centers always using Makita replacement parts OPTIO...

Page 10: ...10...

Page 11: ...11...

Page 12: ...Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan www makita com AT638A ENAU 1604 EN 20160624...

Reviews: