![background image](http://html1.mh-extra.com/html/makita/at638a/at638a_instruction-manual-and-users-manual_3962802007.webp)
7
ENGLISH
1
2
1.
Nose adapter
2.
Contact element
A spare nose adapter is stored in the place shown in
the igure.
1
1.
Spare nose adapter
Connecting air hose
1
2
1.
Air itting
2.
Air socket
Slip the air socket of the air hose onto the air itting on
the stapler. Be sure that the air socket locks irmly into
position when installed onto the air itting.
A hose coupling must be installed on or near the tool in
such a way that the pressure reservoir will discharge at
the time the air supply coupling is disconnected.
OPERATION
CAUTION:
Make sure all safety systems are in
working order before operation.
Selecting the operation mode
CAUTION:
Always make sure that the actua-
tion mode selector is properly set to the position
for the desired stapling mode before stapling.
1
1.
Actuation mode selector
Single sequential actuation mode:
You can drive one staple by one sequential operation.
Select this mode when driving a staple carefully and
accurately.
To choose this mode, set the actuation mode selector to
the
position.
Contact actuation mode:
You can drive staples repetitively by placing the contact
element with the trigger held.
To choose this mode, set the actuation mode selector to
the
position.
Single sequential actuation
Place the contact element against the workpiece and
pull the trigger fully.
After stapling, release the contact element, and then
release the trigger.
2
1