5-9.999Hz  
99.99Hz  

±(1.5% r 6 digits) 

999.9Hz 
9.999KHz 

Range & Resolution

4.8. Frequency Sensitivity: >8Vrms 

Accuracy (% of r digits) 

4.9. Temp (type-K) (probe accuracy not included)

-20.0 to 1000°C  

±(3%rdg + 3°C) 

-4.0 to 1800.0°F  

±(3%rdg + 6°F) 

Range & Resolution

Accuracy (% of r digits) 

-30.0 to 350.0°C  

±(2%rdg + 2°C) 

-22.0 to 662.0°F  

±(2%rdg + 4°F) 

Range & Resolution

4.10. IR Temp (D:S=4:1) 

Accuracy (% of r digits) 

Note:

 Accuracy is given as ±(% of counts of least significant digit) 

at 23

°

C±5°C, with relative humidity less than 80%RH. The precision index 

mentioned above refers to the accuracy of 40%~60% range of each 
measurement range. The accuracy index of the current measured outside 
the measuring range increased by 1.5%, and the accuracy of other 
measurement functions increased by 1%. Check waveform is sine wave. 
Current accuracy assessment shall be based on the position of clamp center. 

Clamp size  

Opening 1.3" (33mm) approx 

TRMS  

The AV voltage and AC current of this meter is 

measured by True RMS. TRMS measurement is 
different from mean measurement. The mean 
measurement method can only measure the 
symmetric waveform, such as sine wave. TRMS 
measurements can reliably measure any 
irregular waveform and obtain valid values for 
AC voltage or AC current. 

Diode Test  

Test current of 0.3mA typical; Open circuit 

voltage 3.2V DC typical. 

Continuity Check  

Threshold <50Ω; Test current < 0.5mA 

Low Battery Indication   "      " is displayed

Range

Basic Functions

4.11. General Specifications

 

Summary of Contents for MT766

Page 1: ...MT766 600A AC DC CLAMP METER WITH IR THERMOMETER INSTRUCTION MANUAL...

Page 2: ...2...

Page 3: ...Temp type K 7 4 10 IR Temp D S 4 1 7 4 11 General Specifications 7 5 Operation 8 5 1 AC DC Current Measurements 8 5 2 AC DC Voltage Measurement 9 5 3 Resistance Measurements 9 5 4 Diode Continuity and...

Page 4: ...his meter can cause damage shock injury or death Read and understand this user manual before operating the meter Always remove the test leads before replacing the battery Inspect the condition of the...

Page 5: ...de 9 Units of measure list AC DC 8 8 8 8 AUTO HOLD C F u m V A K M 3 DISPLAY ICONS 9 Rotary Function switch 10 Data Hold Flashlight button 11 Non contact AC voltage indicator light 12 Non contact AC v...

Page 6: ...ing digits 600 0 1 5 6 digits 6 000K 2 0 5 digits 60 00K 600 0K 2 8 10 digits 6 000M 60 00M 2 8 10 digits Range Resolution 4 5 Resistance Accuracy of reading digits 999 9nF 9 999 F 4 reading 6 digits...

Page 7: ...racy index of the current measured outside the measuring range increased by 1 5 and the accuracy of other measurement functions increased by 1 Check waveform is sine wave Current accuracy assessment s...

Page 8: ...l level appliance portable equipment etc with transient over voltages less than Over voltage Cat III Range Basic Functions 4 11 General Specifications continued 5 1 AC DC Current Measurements 1 Set th...

Page 9: ...nto the negative COM jack and the red test lead banana plug into the positive diode jack 2 Set the function switch to the position 3 Press the MODE button until appears in the display 4 Touch the test...

Page 10: ...roper decimal point and value WARNING To avoid electric shock disconnect both test probes from any source of voltage before making a temperature measurement WARNING To avoid electric shock be sure the...

Page 11: ...he testing range Press once to select MIN press again to select MAX lastly press again to release the MIN MAX recording function 5 13 VFD Button In ACV mode hold down the mode key to enter the VFD mea...

Page 12: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Reviews: