This symbol, adjacent to another symbol or terminal, indicates 

the user must refer to the manual for further information.

This symbol, adjacent to a terminal, indicates that, under 

normal use,hazardous voltages may be present.

 
Double insulation.

Application around and removal from uninsulated hazardous 

live conductors is permitted.

4

1. Safety

!

1.1. lnternational Safety Symbols

1.2. SAFETY NOTES

•   Do not exceed the maximum allowable input range of any function.
•   Do not apply voltage to meter when resistance function is selected.
•   Set the function switch OFF when the meter is not in use.
•   Remove the battery if meter is to be stored for longer than 60 days.

1.3. WARNINGS

•   Set function switch to the appropriate position before measuring.
•   When measuring volts do not switch to current resistance modes.
•   Do not measure current on a circuit whose voltage exceeds 600V.
•   When changing ranges always disconnect the test leads from the circuit 

under test.

1.4. CAUTIONS

!

  Improper use of this meter can cause damage, shock, injury or death. 

Read and understand this user manual before operating the meter.

!

  Always remove the test leads before replacing the battery or fuses.

!

  Inspect the condition of the test leads and the meter itself for any 

damage before operating the meter. Repair or replace if damaged before 
use.

!

  Use great care when making measurements if the voltages are greater 

than 25VAC RMS or 35VDC. These voltages are considered a shock 
hazard.

!

  Always discharge capacitors and remove power from the device under 

test before performing Diode, Resistance or Continuity tests.

!

  Voltage checks on electrical outlets can be difficult and misleading 

because of the uncertainty of connection to the recessed electrical 
contacts. Other means should be used to ensure that the terminals are 
not "live".

!

  If the equipment is used in a manner not specified by the manufacturer, 

the protection provided by the equipment may be impaired.

Summary of Contents for MT730

Page 1: ...INSTRUCTION MANUAL AC TRMS CLAMP METER MT730 II...

Page 2: ...2...

Page 3: ...Measurements 8 3 7 Temperature Measurements 8 3 8 Continuity Measurements 8 3 9 Diode Test 9 3 10 Non Contact AC Voltage Measurements 9 4 Button 9 4 1 MODE VFD Button 9 4 2 HOLD Flashlight Button 10...

Page 4: ...V When changing ranges always disconnect the test leads from the circuit under test 1 4 CAUTIONS Improper use of this meter can cause damage shock injury or death Read and understand this user manual...

Page 5: ...light Button 2 Description 2 1 Meter Description 8 REL and Backlight Button 9 RANGE Button 10 MODE and VFD Button 11 PEAK and INRUSH Button 12 Battery Cover 13 COM Input Jack 14 V CAP TEMP Input Jack...

Page 6: ...l prior to using this meter Set the function select switch to the OFF position when the meter is not in use 3 1 AC Current Measurements WARNING Ensure that the test leads are disconnected from the met...

Page 7: ...e negative COM terminal and the red test lead into the positive V terminal 2 Set the function switch to the VAC position 3 Connect the test leads in parallel to the circuit under test 6 Read the volta...

Page 8: ...tips across the part under test 5 Read the value on the display 6 The display will indicate the proper decimal point and value 3 7 Temperature Measurements 1 Set the function switch to the TEMP positi...

Page 9: ...lways test the Voltage Detector on a known live circuit to verify proper operation 1 Touch the probe tip to the live conductor or insert into the live side of the electrical outlet 2 lf AC voltage is...

Page 10: ...Autorange mode the instrument selects the most appropriate ratio for carrying out measurement If a reading is higher than the maximum measurable value the indication 0L appears on the display Press an...

Page 11: ...put terminals and turn OFF the meter before opening the case Do not operate the meter with an open case 6 1 Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent do not...

Page 12: ...8 digits Function AC True RMS Current Over range protection Maximum input 600A Accuracy specified from 5 to 100 of the measuring range Frequency Response 50Hz to 60Hz True RMS Inrush current Maximum...

Page 13: ...C Voltage Range 45Hz to 1kHz Accuracy of reading digits 1 0 5 digits Function Frequency Sensitivity 20A AC Current Range 20 0 to 80 0 Accuracy of reading digits 1 2 10 digits Function Duty Cycle Resol...

Page 14: ...ayed 0L display 3 readings per second nominal Type K thermocouple 10M VDC and VAC True RMS AAC and VAC 50 1000Hz 5 to 40 C 41 to 104 F 20 to 60 C 4 to 140 F Max 80 up to 31 C decreasing linearly to 50...

Page 15: ...15...

Page 16: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Reviews: