13
(Auto-ranging)
99.99mF
±(5% + 5 digits)
0.01mF
7
9.999µF
0.001µF
99.99µF
±(3.0% + 5 digits)
0.01µF
Range
99.99nF*
999.9nF
Accuracy ±(% of digits)
±(4.5% + 20 digits)
Function
Capacitance
Input Protection: 300V DC or 300V AC RMS.
* < 99.99nF (no specification)
Resolution
0.01nF
0.1nF
999.9µF
0.1µF
9.999mF
0.001mF
Range
10Hz to 100kHz
Accuracy ±(% of digits)
±(1.0% + 5 digits)
Function
Frequency with Test
Input Protection: 1000V AC RMS
Sensitivity: > 15V AC RMS
Frequency (AC Current)
Leads (AC Voltage)
Range
45Hz to 1kHz
Accuracy ±(% of digits)
±(1.0% + 5 digits)
Function
Frequency
Sensitivity: > 20A
(AC Current)
Range
20.0% to 80.0%
Accuracy ±(% of digits)
±(1.2% + 10 digits)
Function
Duty Cycle
Resolution
0.1
Sensor: Type K Thermocouple
Input Protection: 300V DC or 300V AC RMS.
7
Range
-20.0 to 1000°C
-4.0 to 1832°F
Accuracy ±(% of digits)
±(3% + 3°C)
Function
Temperature
Resolution
0.1/1°C
0.1/1°F
±(3% + 5°F)
7
Input Protection: 300V DC or 300V AC RMS.
7
Testing Condition
Forward DCA is approx .1mA,
open circuit voltage MAX 3V
Reading
Forward voltage drop of Diode
Function
Diode
Test current MAX 1.5mA
While resistance is less than (50
Ω
)
Buzzer makes a long sound,
Continuity