background image

INSTRUCTION MANUAL

600V AC/DC BLUETOOTH

MULTIMETER

MT26

Summary of Contents for MT26

Page 1: ...INSTRUCTION MANUAL 600V AC DC BLUETOOTH MULTIMETER MT26...

Page 2: ...2...

Page 3: ...asurements 10 4 1 Low Z AC DC Voltage Measurements 11 4 2 AC Current Measurements 12 4 3 DC Current Measurements 12 4 4 Frequency and Duty Cycle Measurements 13 4 5 Resistance Measurements 13 4 6 Diod...

Page 4: ...re that the test leads are fully seated in the input jacks and keep fingers away from the metal probe tips when taking measurements Before changing functions using the selector switch always disconnec...

Page 5: ...sistance is approx 50 or less Low Battery Indication is displayed Display 4000 count LCD display Over Range Indication OL is displayed Polarity Minus symbol is displayed for negative polarity Measurem...

Page 6: ...ools receptacles and Outlets more than 10m 30ft from a connected loads Cat III source Outlets more than 20m 60ft from a Cat IV source Cat III Three phase circuits Equipment in fixed installations such...

Page 7: ...RMAL TEMPERATURES Temperature extremes can shorten the life of the electronic parts and distort or melt plastic parts 3 HANDLE THE METER GENTLY AND CAREFULLY Dropping it can damage the electronic part...

Page 8: ...light button 10 Flashlight 2 3 SYMBOLS USED ON LCD DISPLAY Volts Amperes Alternating current Direct current Minus sign Hz Hertz frequency Percent duty cycle Ohms Continuity Diode test Farads capacitan...

Page 9: ...isplay The meter will display and hold the maximum reading and will update when a higher max occurs 2 Press the MAX MIN button again to view the lowest reading The MIN indicator meter will appear on t...

Page 10: ...ad to the positive side of the circuit and the black test lead to the negative side of the circuit 5 Read the voltage on the LCD display 4 AC DC VOLTAGE MEASUREMENTS 3 5 HOLD BACKLIGHT BUTTON To freez...

Page 11: ...t AC or DC voltage press the MODE button until the AC or DC symbol appears on the LCD display 3 lnsert the black test lead into the COM input jack and the red test lead into the V input jack 4 Touch t...

Page 12: ...rcuit 6 Read the current on the LCD display 4 3 DC CURRENT MEASUREMENTS WARNINGS Observe all safety precautions when working on live circuits Do not measure current on circuits that exceed 600V Measur...

Page 13: ...the circuit under test 5 Read the frequency or duty cycle on the LCD display 4 5 RESISTANCE MEASUREMENTS 1 Set the rotary function switch to the position 2 Press the MODE button until the symbol appea...

Page 14: ...evices will indicate near 0 and an open device will indicate OL in both polarities WARNING Never test diodes on a live circuit 4 7 CONTINUITY 1 Set the rotary function switch to the position 2 Press t...

Page 15: ...input jack 4 Touch the tip of the Temperature Probe to the object being measured Keep the probe touching the object until the reading stabilizes about 30 sec 5 Read the temperature on the LCD display...

Page 16: ...k do not operate meter until the battery fuse cover is securely fastened to the meter 4 10 FUSE REPLACEMENT 1 Lift up the tilt stand 2 Loosen the two Phillips screws on the battery fuse cover 3 Remove...

Page 17: ...0 1V 1 5 5 600V 1V 5 1 AC VOLTAGE Range Resolution Accuracy 4 000V 1mV 40 00V 10mV 1 5 5 400 0V 0 1V 5 2 LOW Z AC VOLTAGE All AC voltage ranges are specified from 5 of range to 100 of range Input Prot...

Page 18: ...racy 4 000A 1mA 2 0 3 10 00A 10mA 5 6 DC CURRENT Range Resolution Accuracy 400 0 0 1 4 000k 1 1 5 5 40 00k 10 400 0k 100 4 000M 1k 2 0 10 40 00M 10k 5 7 RESISTANCE Input Protection 600V DC or 600V AC...

Page 19: ...tion 600V DC or 600V AC RMS Sensitivity 8V RMS Range Resolution Accuracy 1 0 to 99 9 0 1 1 2 2 5 10 DUTY CYCLE Input Protection 600V DC or 600V AC RMS Pulse Width 0 1 to 100mS Frequency Range 5Hz to 1...

Page 20: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Reviews: