The Majestic Shower Company Limited
One North Place, Edinburgh Way, Harlow Essex
CM20 2SL England,
Tel44 (0) 8448 001 500
Fac44 (0) 1279 635 074
[email protected] www.majesticshowers.com
22
Put the brackets to one side and use the suction glass lifters to
remove the glass inline panel. Remove horizontal inline profile A;
unscrew and remove the vertical wall profile. Drill 7mm holes
where marked on the wall; insert Rawl plugs.
21
Disassemble the remaining two glass-to-wall brackets, being
careful not to damage the faceplates. With the clear plastic
gaskets inserted and wall screw plates facing inwards, align the
brackets centrally to the holes in the glass return panel; hold
them in place and mark the screw holes.
A
B
23
Run a bead of silicone along the wall side of the vertical wall
profile, and screw it tightly into place. Loosely screw the glass-
to-wall brackets to the wall.
A
B
24
Run a bead of silicone along the base of horizontal inline profile
A, and reposition it on the tray or floor where marked; use the
10mm spacer to ensure it is aligned with the vertical wall profile
and push the mitred ends together; tape into position.
Remove the 10mm spacer and apply a small amount of silicone
into the corner joint. Reinsert the noted rubber strips into
horizontal inline profile A.