14
Majestic • DBDV36PLATIN, DBDV36PLATIL, DBDV42PLATIN, DBDV42PLATIL Owner’s Manual • 2454-981 Rev. C • 3/17
K. Detailed Component Operating Instruc-
tions - Intelli
fi
re™ Plus
1. The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 3.6.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or
remote. The unit should be in the OFF position during
installation, service, battery installation, fuel conversion,
and in the event that the control goes into LOCK-OUT
mode as a result of an error code.
ON Position: Appliance will ignite and run continuously
in the HI
fl
ame setting, with no adjustment in
fl
ame
output. This mode of operation is primarily used for
initial installation or power outage operation with battery
backup.
REMOTE Position: Appliance will initiate commands
from an optional wired wall switch and/or the wireless
remote (RC200 or RC300).
2. If using a wired wall switch with the module in REMOTE
mode, the
fl
ame output can be adjusted with the HI/LO
selector switch on the module. See Figure 3.6. Note
that the
fl
ame HI/LO selector switch will become inactive
once an optional remote control (RC200/RC300) is
programmed to the control module. Note that the control
module will always ignite the
fi
replace on HI and remain
so for the initial 10 seconds of operation. If the HI/LO
is switched to the LO position, the
fl
ame output will
automatically drop to the lowest setting after the
fl
ame
has been established for 10 sec. After this 10 second
period, the
fl
ame can be adjusted from HI to LO with
the switch.
3. The control module has safety feature that automatically
shuts down the
fi
replace after 9 hours of continuous
operation without receiving a command from the remote.
4. If you intend to use both an optional wired wall switch
and the RC200 or RC300 remote control to operate your
fi
replace, the wall switch will override any commands
given by the remote.
5.
Module Reset
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into
lock-out mode by emitting three audible beeps, then
continuously displaying a RED/GREEN error code at
its status indicator LED.
• Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section I.
• Locate the module selector switch. (See Figure 3.6).
• Set the module selector switch to the OFF position.
• Wait
fi
ve (5) minutes to allow possible accumulated
gas to clear.
• Set the module selector switch to ON or REMOTE
position.
• Start the appliance.
WARNING! Risk of Explosion! DO NOT
reset the mod-
ule more than one time within a
fi
ve minute time period.
Gas may accumulate in
fi
rebox. Call a quali
fi
ed service
technician.
NG/LP GAS-TYPE
SELECTOR SWITCH
SELECTOR
SWITCH
FLAME HI/LOW
SWITCH
STATUS
INDICATOR LED
MODULE
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically
shuts down the
fi
replace after 9 hours of continuous
operation without receiving a command from the
remote.
Figure 3.6 Control Module
Appliance ON/OFF
A wall control, thermostat or remote control may be used
to control the ON/OFF function of the appliance. Follow
instructions included with the installed control.
Optional Fan Kit
If desired, a fan kit may be added. Contact your dealer
to order the correct fan kit. Heat management for the fan
is discussed in Section 3.H. Detailed instructions are in-
cluded with the fan kit.