Majestic B-Vent Series Installation & Operating Instructions Manual Download Page 5

62D4037

5

BBV, SBV Series Natural Vent Gas Fireplaces

PRODUCT FEATURES

PRODUCT SPECIFICATIONS

• 

This appliance has been certified for use with either 
natural or propane gas. See appropriate data plates.

• 

This appliance is not for use with solid fuels.

• 

The appliance must be installed in accordance with 
local codes if any. If none exist use the current instal-
lation code, ANSI Z223.1/NFPA 54 in the US and 
CSA B149 in Canada.

• 

The appliance must be properly connected to a vent-
ing system.

• 

The appliance is not approved for closet or recessed 
installations.

FP1920
BBV SBV parts 
9/08

Gas Control
(not shown)

1/2” 
Nailing 
Flange

5/8” 
Nailing 
Flanges

1/2” 
Nailing 
Flange

Figure 1 -
BBV/SBV Fireplace

FP1920

HIGH ELEVATIONS

Input ratings are shown in BTU per hour and are cer-
tified  without  deration  for  elevations  up  to  4,500  feet 
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, in-
stallation must be in accordance with the current ANSI 
Z223.1/NFPA  54  and/or  local  codes  having  jurisdic-
tion.
In Canada, please consult provincial and/or local au-
thorities having jurisdiciton for installation at elevations 
above 4,500 feet (1,370 m).

GAS PRESSURES

   

Natural 

Propane (LP)

  Inlet Minimum 

4.5” w.c. 

11.0” w.c.

  Inlet Maximum 

10.5” w.c. 

13.0” w.c.

  Manifold Pressure 

3.5” w.c. 

10.0” w.c.

GAS SPECIFICATIONS & ORIFICE SIZE

 

  

 

Max.Input  Min. Input 

Orifice 

  Model 

Fuel 

BTU/h 

BTU/h 

Size

  400BBVNV 

Nat. 

22,000 

16,000 

#43

  400BBVPV 

LP 

22,000 

14,500 

#55

  400SBVNV 

Nat. 

29,000 

16,500 

#41

  400SBVPV 

LP 

29,000 

16,300 

#53

  500SBVNV 

Nat. 

31,500 

19,000 

#37

  500SBVPV 

LP 

31,500 

20,000 

#52

BEFORE YOU START

Read  this  homeowner  manual  thoroughly  and  follow  all 
instructions  carefully.  Inspect  all  contents  for  shipping 
damage and immediately inform your dealer if any dam-
age is found. Do not install any unit with damaged, incom-
plete, or substitute parts. Check your packing list to verify 
that all listed parts have been received. You should have 
the following:

   Fireplace (Firebox and Burner System)

   Log Set 

  Volcanic Rock

   Rock Wool 

  White Toggle Switch

  Switch Cover Plate 

  Plastic Bag (1)

  Ziplock Bag 2” x 3” x 3”

ITEMS REQUIRED FOR INSTALLATION

  Phillips Screwdriver 

  Framing Materials

  Hammer 

  Wall Finishing Materials

  Saw and/or saber saw 

  Level

  Electric Drill and Bits 

  Tee Joint

  Pliers 

  Measuring Tape

  Square 

  Pipe Wrench

  Caulking Material (Noncombustible)

  Fireplace Surround Material (Noncombustible)

  Piping Complying with Local Codes

  Pipe Sealant Approved for use with Propane/LPG

  (Resistant to Sulfur Compounds)

Summary of Contents for B-Vent Series

Page 1: ...ency or the gas supplier WARNING Improper installation adjustment alteration services or maintenance can cause injury or property damage Refer to this man ual For assistance or additional information...

Page 2: ...ecautions 10 Installation Planning 10 Firestops 11 Termination 11 Outside Combustion Air 12 Combustion Air Assembly 13 Fireplace Installation 14 Check Gas Type 14 Installing Gas Piping to Fireplace Bu...

Page 3: ...tions 4 Never install the fireplace in a recreational vehicle where curtains furniture clothing or other flam mable objects are less than 42 from the front top or sides of the fireplace in high traff...

Page 4: ...eat exchanger fire place or any other accessory not approved for use with this fireplace 21 The fireplace is not intended for use with a thermo stat 22 This appliance must be installed with draft hood...

Page 5: ...00 feet 1 370 m GAS pressures Natural Propane LP Inlet Minimum 4 5 w c 11 0 w c Inlet Maximum 10 5 w c 13 0 w c Manifold Pressure 3 5 w c 10 0 w c Gas Specifications ORIFICE SIZE Max Input Min Input O...

Page 6: ...6 7 7 8 m m 43 6 1102 mm 624037 400BBV dims 6 152 mm Figure 2 400BBV Fireplace Dimensions and Framing FIREPLACE FRAMING Firebox framing can be built before or after the appliance is set in place Cons...

Page 7: ...D Min Rough Opening Width 656O 165 mm 13 6QE 341 mm C E F G G 6 152 mm Figure 3 400SBV 500SBV Fireplace Dimensions and Framing Ref 400SBV 500SBV A 40 1016 mm 46 1168 mm B 36 914 mm 42 1067 mm C 24ZC z...

Page 8: ...front opening of the fireplace Do not install in the vicinity where gasoline or other flammable liquids may be stored Vent pipe routing Refer to Venting section found in this manual for allowable vent...

Page 9: ...ge 5 8 Nail Flange 5 8 Nail Flange FP2019 Figure 6 Secure Fireplace to Floor and Framing Studs FINISHING MATERIAL NOTE Any remote wiring i e remote control and wall switch must be done prior to final...

Page 10: ...e appliance collar The B vent outer wall will slip to the outside of the appliance collar Do not penetrate the pipe inner line with sheet met al screws Attach the initial flue section tot he top of th...

Page 11: ...on should be considered a combustible ma terial Maintain proper clearances to all combustible materials NOTICE Treatment of firestops and construction of the chase may vary from building type to build...

Page 12: ...e the location cannot be accidentally blocked Locate assembly above snow line to prevent snow from blocking assembly 3 Never mount combustion air inlet assem bly in garage or storage area where com bu...

Page 13: ...andard pocket knife Figure 12 WARNING DO NOT remove the cover if the outside air will not be connected WARNING Do not use a combustible duct Always use UL Listed Class 0 or 1 duct material If nec essa...

Page 14: ...urner system regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 14 Pointing the vent down protects it from freezing rain or sleet WARNING A qualifie...

Page 15: ...f the gas to the fireplace Check your building codes for any special requirements for locating equipment shut off valve to fireplaces Apply pipe joint sealant lightly to male threads This will pre ven...

Page 16: ...s from the gas meter to the fireplace for leaks Use a solution of 50 50 water and soap or a gas sniffer 4 To adjust flame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob...

Page 17: ...nly be performed by a qualified licensed electrician Main power must be off when connecting to main electrical power supply or performing service All wiring shall be in compliance with all local city...

Page 18: ...gram FP2027 REMOTE WALL SWITCH Position the wall switch Do not extend beyond the 15 of wire OPTIONAL DC REMOTE SYSTEMS These instructions replace the section entitled Hearth Mount in the Millivolt han...

Page 19: ...sooting LOG PLACEMENT Figure 19 1 Place rear log 1 on grate assembly Log should rest firmly on the two log mounting pins on the horizontal bars 2 Place bottom left log 2 on grate Rest the back side o...

Page 20: ...the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it Call a qualified service technicia...

Page 21: ...r WARNING If using a soap and water solu tion to test for leaks DO NOT spray solution onto control body DANGER Never check for gas leaks with open flame NOTE Remove any excessive pipe compound from th...

Page 22: ...the button is in the ON posi tion to light the main burner Figure 21 LIGHTING THE BURNER Depress and turn the knob counterclockwise to the ON position Fig ure 22 It will take less than four 4 seconds...

Page 23: ...ce if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any pat of the control system and any gas control that has been under...

Page 24: ...e pilot flame must always be present when the fireplace is in operation Figure 26 The pilot flame has three distinct flames one engulfing the thermopile one engulfing the thermo couple and the other r...

Page 25: ...uum surface of the logs with a brush attachment If logs must be removed for cleaning handle carefully by holding gently at each end Gloves are recom mended to prevent skin irritation from ceramic fibe...

Page 26: ...62D4037 26 BBV SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS FIREBOX COMPONENTS 4a 4b 4c 6 3 6 FIREBOX PARTS 1 2 3 5 6 7...

Page 27: ...t Refractory 1 n a 62D1017 62D2017 Optional Field Installed Accessoriesd 5 Firebrick Assembly 1 F400BBVW n a n a 6 Outside Air Kit 1 OAC4 OAC4 OAC4 7 Black Glass Door Assembly 1 GD36BA GD36BA GD36BA 7...

Page 28: ...62D4037 28 BBV SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS STANDING PILOT MILLIVOLT CONTROL 1 2 3 4 5 6 7 8 10 12 13 2T 2I 2C 9 11 6 3 6 CONTR PARTS...

Page 29: ...3D6046 23D6046 23D6046 5 Rocker Switch 1 41D0048 41D0048 41D0048 41D0048 41D0048 41D0048 6 Piezo Igniter 1 14D0503 14D0503 14D0503 14D0503 14D0503 14D0503 7 Injector 1 62D3006 62D3005 62D3004 20H3143...

Page 30: ...62D4037 30 BBV SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS ELECTRONIC IGNITION 1 2 3 4 5 6 7 9 8 10 11 12 6 3 6 ELECTRONIC IGNITION PARTS...

Page 31: ...h Shut off Valve 1 23D6046 23D6046 23D6046 23D6046 23D6046 23D6046 5 Rocker Switch 1 41D0048 41D0048 41D0048 41D0048 41D0048 41D0048 6 Injector 1 62D3006 62D3005 62D3004 20H3143 62D3003 62D0094 7 Burn...

Page 32: ...mocouple connection at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one mil livolt lead wire on the tip of the thermocouple and the other meter lead wire...

Page 33: ...er ori es blocked B Check electrical connections between module and pilot operator on gas control C Check for 24VAC across PV MVPV terminals If voltage is correct replace gas control If voltage is not...

Page 34: ...air pressure A Blockage or restriction in venting ACTION A Install log set per instructions Inspect the injector and air intake area Make sure this area does not have any blockage from debris and clea...

Page 35: ...62D4037 35 BBV SBV Series Natural Vent Gas Fireplaces...

Page 36: ...62D4037 36 BBV SBV Series Natural Vent Gas Fireplaces...

Page 37: ...62D4037 37 BBV SBV Series Natural Vent Gas Fireplaces...

Page 38: ...o comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Pl...

Page 39: ...he Limited Lifetime Warranty will also be void if the appliance is not operated and main tained according to the operating instructions supplied with the appliance and does not extend to 1 firebox bur...

Page 40: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Reviews: