background image

62D4037

20

BBV, SBV Series Natural Vent Gas Fireplaces

OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

W

ARNING

If  you  do  not  follow  these  instructions 
exactly,  a  fire  or  explosion  may  result 
causing  property  damage,  personal  in-
jury or loss of life.

A.

 This appliance is equipped with a pilot which must be lit with an ignitor while following these instructions exactly.

B.

 BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because 

some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

• 

Turn off all gas to the appliance.

• 

Open windows.

• 

Do not attempt to light any appliance.

• 

Do not touch any electric switch; do not use any phone in your building.

• 

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

• 

If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will not push in or turn 

by hand, don’t try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or 
explosion.

D. Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician 

to inspect the appliance and to replace any pat of the control system and any gas control that has been under 
water.

LIGHTING PILOT FOR THE FIRST TIME

INITIAL LIGHTING

Purge air from the supply line as follows:

• 

Open main shut-off valve.

• 

Unscrew main pressure test point.

• 

Leave inlet test screw open until gas comes in.

• 

When gas is flowing, tighten inlet screw immediately.

LEAK TESTING

1.  Follow the pipe from the gas supply line connection to the gas valve. Check connection for leaks with soap and 

water mixture.

2.  Next check for gas leaks at the burner with soap and water mixture.
3.  Check the pilot for gas leaks with soap and water mixture.

W

ARNING

Never  use  an  open  flame  to  check  for 
gas leaks.

Summary of Contents for B-Vent Series

Page 1: ...ency or the gas supplier WARNING Improper installation adjustment alteration services or maintenance can cause injury or property damage Refer to this man ual For assistance or additional information...

Page 2: ...ecautions 10 Installation Planning 10 Firestops 11 Termination 11 Outside Combustion Air 12 Combustion Air Assembly 13 Fireplace Installation 14 Check Gas Type 14 Installing Gas Piping to Fireplace Bu...

Page 3: ...tions 4 Never install the fireplace in a recreational vehicle where curtains furniture clothing or other flam mable objects are less than 42 from the front top or sides of the fireplace in high traff...

Page 4: ...eat exchanger fire place or any other accessory not approved for use with this fireplace 21 The fireplace is not intended for use with a thermo stat 22 This appliance must be installed with draft hood...

Page 5: ...00 feet 1 370 m GAS pressures Natural Propane LP Inlet Minimum 4 5 w c 11 0 w c Inlet Maximum 10 5 w c 13 0 w c Manifold Pressure 3 5 w c 10 0 w c Gas Specifications ORIFICE SIZE Max Input Min Input O...

Page 6: ...6 7 7 8 m m 43 6 1102 mm 624037 400BBV dims 6 152 mm Figure 2 400BBV Fireplace Dimensions and Framing FIREPLACE FRAMING Firebox framing can be built before or after the appliance is set in place Cons...

Page 7: ...D Min Rough Opening Width 656O 165 mm 13 6QE 341 mm C E F G G 6 152 mm Figure 3 400SBV 500SBV Fireplace Dimensions and Framing Ref 400SBV 500SBV A 40 1016 mm 46 1168 mm B 36 914 mm 42 1067 mm C 24ZC z...

Page 8: ...front opening of the fireplace Do not install in the vicinity where gasoline or other flammable liquids may be stored Vent pipe routing Refer to Venting section found in this manual for allowable vent...

Page 9: ...ge 5 8 Nail Flange 5 8 Nail Flange FP2019 Figure 6 Secure Fireplace to Floor and Framing Studs FINISHING MATERIAL NOTE Any remote wiring i e remote control and wall switch must be done prior to final...

Page 10: ...e appliance collar The B vent outer wall will slip to the outside of the appliance collar Do not penetrate the pipe inner line with sheet met al screws Attach the initial flue section tot he top of th...

Page 11: ...on should be considered a combustible ma terial Maintain proper clearances to all combustible materials NOTICE Treatment of firestops and construction of the chase may vary from building type to build...

Page 12: ...e the location cannot be accidentally blocked Locate assembly above snow line to prevent snow from blocking assembly 3 Never mount combustion air inlet assem bly in garage or storage area where com bu...

Page 13: ...andard pocket knife Figure 12 WARNING DO NOT remove the cover if the outside air will not be connected WARNING Do not use a combustible duct Always use UL Listed Class 0 or 1 duct material If nec essa...

Page 14: ...urner system regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 14 Pointing the vent down protects it from freezing rain or sleet WARNING A qualifie...

Page 15: ...f the gas to the fireplace Check your building codes for any special requirements for locating equipment shut off valve to fireplaces Apply pipe joint sealant lightly to male threads This will pre ven...

Page 16: ...s from the gas meter to the fireplace for leaks Use a solution of 50 50 water and soap or a gas sniffer 4 To adjust flame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob...

Page 17: ...nly be performed by a qualified licensed electrician Main power must be off when connecting to main electrical power supply or performing service All wiring shall be in compliance with all local city...

Page 18: ...gram FP2027 REMOTE WALL SWITCH Position the wall switch Do not extend beyond the 15 of wire OPTIONAL DC REMOTE SYSTEMS These instructions replace the section entitled Hearth Mount in the Millivolt han...

Page 19: ...sooting LOG PLACEMENT Figure 19 1 Place rear log 1 on grate assembly Log should rest firmly on the two log mounting pins on the horizontal bars 2 Place bottom left log 2 on grate Rest the back side o...

Page 20: ...the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it Call a qualified service technicia...

Page 21: ...r WARNING If using a soap and water solu tion to test for leaks DO NOT spray solution onto control body DANGER Never check for gas leaks with open flame NOTE Remove any excessive pipe compound from th...

Page 22: ...the button is in the ON posi tion to light the main burner Figure 21 LIGHTING THE BURNER Depress and turn the knob counterclockwise to the ON position Fig ure 22 It will take less than four 4 seconds...

Page 23: ...ce if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any pat of the control system and any gas control that has been under...

Page 24: ...e pilot flame must always be present when the fireplace is in operation Figure 26 The pilot flame has three distinct flames one engulfing the thermopile one engulfing the thermo couple and the other r...

Page 25: ...uum surface of the logs with a brush attachment If logs must be removed for cleaning handle carefully by holding gently at each end Gloves are recom mended to prevent skin irritation from ceramic fibe...

Page 26: ...62D4037 26 BBV SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS FIREBOX COMPONENTS 4a 4b 4c 6 3 6 FIREBOX PARTS 1 2 3 5 6 7...

Page 27: ...t Refractory 1 n a 62D1017 62D2017 Optional Field Installed Accessoriesd 5 Firebrick Assembly 1 F400BBVW n a n a 6 Outside Air Kit 1 OAC4 OAC4 OAC4 7 Black Glass Door Assembly 1 GD36BA GD36BA GD36BA 7...

Page 28: ...62D4037 28 BBV SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS STANDING PILOT MILLIVOLT CONTROL 1 2 3 4 5 6 7 8 10 12 13 2T 2I 2C 9 11 6 3 6 CONTR PARTS...

Page 29: ...3D6046 23D6046 23D6046 5 Rocker Switch 1 41D0048 41D0048 41D0048 41D0048 41D0048 41D0048 6 Piezo Igniter 1 14D0503 14D0503 14D0503 14D0503 14D0503 14D0503 7 Injector 1 62D3006 62D3005 62D3004 20H3143...

Page 30: ...62D4037 30 BBV SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS ELECTRONIC IGNITION 1 2 3 4 5 6 7 9 8 10 11 12 6 3 6 ELECTRONIC IGNITION PARTS...

Page 31: ...h Shut off Valve 1 23D6046 23D6046 23D6046 23D6046 23D6046 23D6046 5 Rocker Switch 1 41D0048 41D0048 41D0048 41D0048 41D0048 41D0048 6 Injector 1 62D3006 62D3005 62D3004 20H3143 62D3003 62D0094 7 Burn...

Page 32: ...mocouple connection at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one mil livolt lead wire on the tip of the thermocouple and the other meter lead wire...

Page 33: ...er ori es blocked B Check electrical connections between module and pilot operator on gas control C Check for 24VAC across PV MVPV terminals If voltage is correct replace gas control If voltage is not...

Page 34: ...air pressure A Blockage or restriction in venting ACTION A Install log set per instructions Inspect the injector and air intake area Make sure this area does not have any blockage from debris and clea...

Page 35: ...62D4037 35 BBV SBV Series Natural Vent Gas Fireplaces...

Page 36: ...62D4037 36 BBV SBV Series Natural Vent Gas Fireplaces...

Page 37: ...62D4037 37 BBV SBV Series Natural Vent Gas Fireplaces...

Page 38: ...o comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Pl...

Page 39: ...he Limited Lifetime Warranty will also be void if the appliance is not operated and main tained according to the operating instructions supplied with the appliance and does not extend to 1 firebox bur...

Page 40: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Reviews: