11
360DVS Series Direct Vent Fireplaces
10006326
FP1430
Fig. 8
Alternate switch location.
Optional Top Vent Application
This appliance is shipped as a rear vent unit. If the
installation layout requires the unit to be a top vent con-
figuration, the appliance can be converted by following
the steps below.
When removing and refitting the plates and
adapter, be sure the associated gasket is
undamaged and refitted as required.
1. Remove the ten (10) screws securing the outer col-
lar adapter to the fireplace body. (Fig. 9)
2. Set the collar aside, complete with the gasket.
NOTE: Do not damage the gasket, as the adapter
and gasket must be refitted.
3. Remove the insulation material (exposed in Step
2) from the top of the unit. (Fig. 10) This material
can be discarded; however, if the unit is converted
back to rear-vent, a new piece of insulation material
approved by CFM Corporation must be used for this
purpose.
NOTE:
When converting appliance to top vent,
ensure the insulation material referred to in step 3 is
completely removed.
4. Remove the 4 screws securing the flue cover plate
to the top of the intake box and remove the cover
and gasket. (Fig. 11)
5. Remove 4 screws securing the flue pipe to back of
the intake box and remove pipe and gasket. (Fig. 11)
6. Secure the plate and gasket removed in step 4 over
the flue opening in the back of the intake box. En-
sure the gasket is in place and undamaged.
7. Install the flue pipe and gasket removed in step 5
over the flue opening in the top of the intake box.
8. Refit the outer collar adapter and gasket to the unit
with the round collar on the top. Secure the adapter
with the 10 screws removed in step 1.
FP1431
top vent
remove screws
Remove These Screws
Remove
These
Screws
Outer Collar Adapter
FP1431
Fig. 9
Remove screws from outer collar adapter.
FP1432
remove flue cover
and pipe
Insulation Pad
(Must be removed)
Flue
Pipe
FP1432
Fig. 10
Remove flue cover and pipe.
FP1433
flue cover plate
Flue Cover
Plate
Flue
Pipe
FP1433
Fig. 11
Flue pipe removal.