7
LDVR Series Direct Vent Gas Fireplace
10007317
A hearth is not mandatory but is recommended for aes-
thetic purposes. We recommend a noncombustible hearth
which projects out 1” (305mm) or more from the front of
the fireplace.
Cold climate installation recommendation:
When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be insulated
to conform to applicable insulation codes.
Hearth
Noncombustible materials such as brick or tile may be
extended over the edges of the face of the fireplace.
DO
NOT
cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the
brick or tile will have to be installed flush with the edges
of the fireplace.
Final Finishing
Framing and Finishing
Inlet Minimum
5.5” w.c.
11.0” w.c.
Inlet Maximum
14.0” w.c.
14.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
Gas Inlet and Manifold Pressures
Natural
LP (Propane)
Check fireplace to make sure it is levelled
and properly positioned.
To mount the appliance:
1. Choose the location.
. This unit comes with four (4) flanges pre-mounted on
both sides of the fireplace to allow two different drywall
thicknesses to be used. Flange “A” is for 1/” drywall
while flange “B” is for 5/8” drywall.
3. Bend the desired flanges out 90° on both sides of the
fireplace. Slide the fireplace into the framed opening
until the flanges contact the front surfaces of the fram-
ing. Level the unit and secure it firmly in place.
FP1544
nail flange
1/05
Fig. 4
Nailing flanges.
Flange
Drywall
Position
Depth
A
1/” / 13 mm
B
5/8” / 16 mm
Flange Location for
Desired Drywall Depth
FP1539
A
B
*Using conversion kit
Max.
Min.
Gas
Input
Input
Model
Fuel
Control
BTU/h
BTU/h
33LDVRRN
Nat
Millivolt
16,000
11,00
33LDVRRP
Prop
Millivolt
16,000
1,000
33LDVREN
Nat
4V Hi/Lo
16,000
11,00
33LDVREP
Prop*
4V Hi/Lo
16,000
1,000
33LDVRIN
Nat.
6V DC Hi/Lo 16,000
11,00
33LDVRIP*
Prop.* 6V DC Hi/Lo 16,000
1,000
36LDVRRN
Nat
Millivolt
19,500
13,650
36LDVRRP
Prop
Millivolt
19,500
14,65
36LDVREN
Nat
4V Hi/Lo
19,500
13,650
36LDVREP
Prop*
4V Hi/Lo
19,500
14,65
36LDVRIN
Nat.
6V DC Hi/Lo 19,500
13,650
36LDVRIP*
Prop.* 6V DC Hi/Lo 19,500
14,65
39LDVRRN
Nat
Millivolt
3,000
16,100
39LDVRRP
Prop*
Millivolt
,500
16,875
39LDVREN
Nat
4V Hi/Lo
3,000
16,100
39LDVREP
Prop*
4V Hi/Lo
,500
16,875
39LDVRIN
Nat.
6V DC Hi/Lo 3,000
16,100
39LDVRIP*
Prop.* 6V DC Hi/Lo 3,000
16,875
43LDVRRN
Nat
Millivolt
6,000
18,00
43LDVRRP
Prop*
Millivolt
4,000
18,000
43LDVREN
Nat
4V Hi/Lo
6,000
18,00
43LDVREP
Prop*
4V Hi/Lo
4,000
18,000
Gas Specifications
Air Shutter Adjustment
Model
Gas Type Air Shutter Opening
33LDV
Natural
3/16” Open
36/39/43LDV
Natural
Top & Bottom
Hole Half Closed
33/36/39/43LDV
Propane
Fully Open