44
LDVR Series Direct Vent Gas Fireplace
10007317
Ceramic refractory panels are available in kit form for the
LDV series appliances
Kit Model and Finish
Unit
Sandstone
Red
Black
Grey
33LDVR 33LDVRCR
36LDVR GAHC3J0 GAFC3J0 GABC3J0 GAGC3J0
39LDVR 39LDVCR
43LDVR 43LDVCR
Ceramic Refractory Panels
The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the absence
of local codes, with the current CSA C22.1
Canadian Electric Code.
For USA installations follow the local codes
and the national electrical code ANSI/NFPA
No. 70.
Should this fan require servicing or repair
the power supply must be disconnected. For
rewiring of any replacement parts refer to
Figure 57.
Any electrical rewiring of this fan must be
done by a licensed electrician.
Wiring Instructions
Black
White
Ground
FP394
WIRING DIAGRAM
11/20/96
Speed
Control
Temperature Sen-
sor
Fan
FP105
Fig. 57
FK4 fan wiring.
Take care when handling the refractory panels
as they are fragile until held in place and
supported.
Installation
Refer to Figures 58 & 59
1. Remove the front window frame assembly.
. Remove the logs.
3. Place the rear refractory panel in place. Locate the lower
edge of the panel in the ledge formed by the top of the
rear log support bracket.
4. Slide the side refractory panels into place to hold the
rear panel secure. Repeat the procedure on the other
side.
5. Replace the logs and window frame assembly.
For aesthetic purposes we recommend aligning the
horizontal mortar lines.
FP1231
Ceramic panels
11/02
Side
Panel
Side
Panel
Log Support
Burner Tray
Back Panel
FP131
Fig. 58
Ceramic panel installation.
FP1232
rear ceramic panel
11/02
Rear Refrac-
tory Panel
Firebox Back
Panel
Rear Panel
Support
Brackets
Rear Log
Support
FP13
Fig. 59
Rear refractory panel installation.
Remote Controls
Optional remote control units are available to control different
functions of the appliances
Model
Function/s Controlled
RCI
ON/OFF
RC
ON/OFF and Temperature
IMTFK
Wall mounted thermostat control
(must be used in bedroom installations)