BDVT Series Direct Vent GaS Fireplace

10003358

The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electric Code.

For USA installations follow the local
codes and the national electrical code
ANSI/NFPA No. 70.

Should this fan require servicing or
repair the power supply must be
disconnected. For rewiring of any
replacement parts refer to Figure 50.

Any electrical re-wiring of this fan must
be done by a licensed electrician.

Wiring Instructions

Black

White
Ground

Fan

Temperature Sensor

Speed Control

FP1025

Fig. 50  FK24 fan wiring.

Ceramic refractory panels are available in kit form for
the BDV series appliances

Appliance Model

Kit Name

33BDVT

AT1TBT

33BDVR

AT1CBB

36BDVT

BT2CBB

39BDVT

CT2CBB

43BDVT

DT2CBB

6. Place the rear refractory panel in place. Locate the

lower edge of the panel in the ledge formed by the
top of the rear log support bracket.

7. Slide the side refractory panels into place to hold

the rear panel secure. Adjust the top adjustable
tabs to hold the side panel against the firebox wall
and secure the tab. Repeat the procedure on the
other side.

8. Replace the logs and window frame assembly.

For esthetic purposes we recommend
lining up the horizontal mortar lines.

Ceramic Refractory Kits

Take care when handling the refractory
panels as they are fragile until held in
place and supported.

Installation, refer to Figures 51 & 52

1. Remove the front window frame assembly.
2. Remove the logs.
3. Place the lower supports for the side refractory

panels on the base of the firebox. Place each
support so that the slotted hole fits over the forward
screw head along the edge of the base.

4. Lay the angular base panels in place on the floor of

the firebox on either side of the burner housing
assembly.

5. Loosely attach the top adjustable tabs to the studs

located in the top of the firebox toward the front
corners.

Adjustable
Tab

Side
Panel

Floor
Refractory
Panel

Lower Side Supports

Adjustable
Tab

Side
Panel

Floor
Refractory
Panel

Log Support

Burner Tray

Back Panel

FP1231

Fig. 51  Ceramic panel installation.

Rear Refractory
Panel

Rear Panel
Support Brackets

Rear Log
Support

Firebox Back
Panel

FP1232

Fig. 52  Rear refractory panel installation.

An optional front window screen is available for the
36BDV, 39BDV and 43BDV.

Appliance Model

Kit Name

36BDVT/36BDVR

BTISOB

39BDVT/39BDVR

CTISOB

43BDVT/43BDVR

DTISOB

Installation, refer Figure 53.

DO NOT ATTEMPT to install or remove
the screen while the appliance is hot.

Front Window Screen

Summary of Contents for 33BDVT

Page 1: ...e gas suppliers instructions If you cannot reach your gas supplier call the fire department WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLO SION MAY RESULT CAUSING PR...

Page 2: ...17 Twist Lock Venting Components 19 Operating Instructions Glass Information 20 Louvre Removal 20 Window Frame Assembly Removal 20 Glass Cleaning 20 Installation of Logs Lava Rock Ember Material 21 Fl...

Page 3: ...our and liquids This fireplace should not be used as a dry ing rack for clothing nor should Christmas stockings or decorations be hung on or around the fireplace 9 Under no circumstances should any so...

Page 4: ...31 787mm 33 838mm 36 914mm 40 1016mm D 16 416mm 21 533mm 21 533mm 23 570mm E 22 559mm 24 610mm 24 610mm 31 787mm F 14 356mm 16 406mm 16 406mm 16 406mm G 31 810mm 37 946mm 37 946mm 40 1016mm H 6 152mm...

Page 5: ...g of a bay window trim kit does not effect the distances and reference points referred to in the diagram and chart Noncombustible mantels and legs may be installed at any height and width around the a...

Page 6: ...ll strip to confirm the final depth High Elevations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370m above sea level For elevations abo...

Page 7: ...es Do not wire the remote ON OFF wall switch for the gas fireplace to the 120 volt power supply Always check for gas leaks with a mild soap and water solution Do not use an open flame for leak testing...

Page 8: ...els of the appliance Take care not to cut the wire or insulation on metal edges Route the wire to a conveniently located receptacle box 2 Attach the wire to the ON OFF switch and install the switch in...

Page 9: ...gs within 24 610mm from the front of the termination hood General Venting Do not locate termination hood where excessive snow or ice build up may occur Be sure to check vent termination area after sno...

Page 10: ...assembly 5m above the meter regulator assy I Clearance to service regulator vent outlet 3 91cm 3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances t...

Page 11: ...le exteriors A Combustible 6 152mm Noncombustible 2 52mm B Combustible 6 152mm Noncombustible 2 52mm A Balcony with no side wall G Combustible Noncombustible 12 305mm G Balcony with perpendicular side...

Page 12: ...Sidewall Applications How to Use the Vent Graph The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizo...

Page 13: ...m vent run with elbows 1 2 3 4 Example Elbow 1 90 Elbow 2 45 Elbow 3 45 Elbow 4 90 Total angular variation 270 1 2 3 4 270 FP1239 Fig 16 Maximum number of elbow degrees STEP 1 Locate vent opening on t...

Page 14: ...20 Horizontal length requirement Max Length 12 305mm 8 Screws 2 8 Screws 2 Adjustable Zero Clearance Sleeve 8 Screws 2 Adjustable Zero Clearance Sleeve ZCS101 Fig 18 Adjustable zero clearance sleeve...

Page 15: ...adhesive You may also attach the termination with screws through the inner body into the 4 102mm vent pipe however for this method you must extend the 4 102mm pipe approximately 6 152mm beyond the out...

Page 16: ...en elbows Fig 26 7DVCS must be used to support offsets Fig 31 This application will require that you first determine the roof pitch and use the appropriate starter kit Refer to Venting Components List...

Page 17: ...se screws to attach the restrictor plate FP1247 Fig 28 Remove two 2 top screws then place restrictor plate The legs of the restrictor plate must go down FP1248 Fig 29 Place restrictor with legs pointi...

Page 18: ...l Ceiling Support Application CFM110 Fig 31 Roof and ceiling supports Min 2 610 mm CFM190 Fig 33 Minimum termination to roof clearance 7 Install roof support Fig 31 and roof flashing making sure upper...

Page 19: ...Termination 7TDVSNORK for Below Grade Installation 45 Elbow 7TDV45 for Vertical Horizontal Offset 90 Transition Elbow 7TDVRT90 for Rear Vent to Vertical Vent 90 Elbow 7TDV90 for Vertical Horizontal Of...

Page 20: ...y deposit a slight film on the glass It is therefore recommended that the glass be cleaned two or three times with a non ammonia based household cleaner and warm water We recommend gas fireplace glass...

Page 21: ...separate it when unpacked and keep it in a loose condition 7 Scatter the lava rock material around the firebox base Do not place any of the lava rock material on the burner housing assembly 36BDVT Re...

Page 22: ...round the firebox base Do not place any of the lava rock material on the burner housing assembly 39BDVT Refer to Figure 38 1 Remove the top louvre assembly 2 Remove the window frame assembly 3 Fit the...

Page 23: ...for service and adjustment Flame Characteristics Flame Temperature Adjustment L O HI Turn counterclockwise to decrease flame height Turn clockwise to increase flame height Fig 40 Flame adjustment knob...

Page 24: ...ally When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and wi...

Page 25: ...n by hand do not try to repair it call a qualified service technician Force or attempting repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediat...

Page 26: ...All Wiring Connections Replace Piezo Ignitor Supply Line Hooked Up Shutoff Valve Open Pilot Stays Lit For Air In The Lines Thermopile Needs A Min 325mv Adjust Pilot Flame Height All Wiring Connection...

Page 27: ...r wire accross terminals at wall switch if burner comes on replace defective wall switch If okay jumper wires across wall switch wires at valve if burner comes on wires are faulty or connections are b...

Page 28: ...UPPLY TUBING AND PRESSURES ARE GOOD AND PILOT BURNER ORIFICE IS NOT BLOCKED CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND PILOT OPERATOR ON GAS CONTROL CHECK FOR 24VAC ACROSS PV MVPV TERMINALS ON MO...

Page 29: ...ulator mounting screws A pressure regulator tower B and diaphram C b Ensure the rubber gasket D is properly positioned and install the new Hi Lo pressure regulator to the valve using the new screws E...

Page 30: ...rmopile millivolt gas valve Most of these components may require only an occasional checkup and cleaning and some may require adjustment If repair is necessary it should be performed by a qualified te...

Page 31: ...2a b 16 11 20 24 15 8 7 5 3a b 4a b 19 21 22 23 6 10 25 9 26 1f 1h 1b 33BDVT 1c 1a 1b 1f 1a 1e 1g 1c 1a 1d 1b 36BDVT 39BDVT 43BDVT CFM Specialty Home Products reserves the right to make changes in des...

Page 32: ...rifice SIT Top Convertible Nat 10002268 10002268 10002268 10002268 Pilot orifice SIT Top convertible Prop 10002269 10002269 10002269 10002269 6 Pilot hood SIT Top convertible 10002385 10002385 1000238...

Page 33: ...81 55686 57437 57438 Gasket window glass 57317 57317 57317 57317 20 Clamp window frame assembly 54174 54174 54174 54174 21 Window trim polished brass w magnets 55005 57480 57483 57485 22 Top louvre as...

Page 34: ...ed to the unit to a conveniently located wall socket Method B Using EB 1 Receptacle Box The EB 1 receptacle box Pt ZA1200 may be hard wired into the house supply The fan lead is then plugged into the...

Page 35: ...er side 8 Replace the logs and window frame assembly For esthetic purposes we recommend lining up the horizontal mortar lines Ceramic Refractory Kits Take care when handling the refractory panels as t...

Page 36: ...Remote Controls Decorative Bay Windows Bay Window Screen Bay Window Screen Kits are available for the 33BDVT 36BDVT 39BDVT 43BDVT model appliances Do not remove existing window frame assembly Remove...

Page 37: ...upon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisi...

Page 38: ...9 76 80 58 36BDVTRP 48 9 77 80 58 36BDVTEN 48 9 76 80 58 36BDVTEP 48 9 77 80 58 39BDVTRN 61 8 77 78 63 39BDVTRP 61 8 78 79 63 39BDVTEN 61 8 77 78 63 39BDVTEP 61 8 78 79 63 43BDVTRN 61 8 77 78 63 43BD...

Reviews: