23
BDVT Series Direct Vent GaS Fireplace
10003358
RN/RP & EN/EP Models
For units equipped with ‘HI/LO’ valves the flame
adjustment is accomplished by rotating the ‘HI/LO’
adjustments knob located near the center of the gas
control valve. (Fig. 40 & 41)
It is important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
pictorials illustrated below (Fig. 42-46).
If the flame patterns appear abnormal contact a
qualified service provider for service and adjustment.
Flame Characteristics
Flame & Temperature Adjustment
LO
HI
Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
Fig. 40 Flame adjustment knob for Honeywell valve.
LO
HI
Turn
counterclockwise
to increase
flame height
Turn clockwise
to decrease
flame height
Fig. 41 Flame adjustment knob for SIT valve.
LG271
Fig. 43 Correct burner flame appearance for 33BDVT.
LG272
Fig. 44 Correct burner flame appearance for 36BDVT.
LG273
Fig. 45 Correct burner flame appearance for 39BDVT.
LG274
Fig. 46 Correct burner flame appearance for 43BDVT.
SIT Top Convertible
SIT EN/EP
FP1229
Fig. 42 Correct pilot flame appearance.
SIT