33/36/39/43 BDVT
-22-
10002555/0
Vermont Castings, Majestic Products.
F
LAME
& T
EMPERATURE
A
DJUSTMENT
RN/RP & EN/EP Models
For units equipped with ‘HI/LO’ valves the ame adjustment
is accomplished by rotating the ‘HI/LO’ adjustment knob
located near the centre of the gas control valve, Fig. 47 & 48
Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
Honeywell Valve
Turn
counterclockwise
to increase
flame height
Turn clockwise
to decrease
flame height
SIT 820 Valve
F
LAME
C
HARACTERISTICS
It is important to periodically perform a visual check of the
pilot and burner ames. Compare them to the pictorials illus-
trated below, Figs. 49 - 53.
If the ame patterns appear abnormal contact a qualied ser-
vice provider for service and adjustment.
33BDVT
36BDVT
39BDVT
43BDVT
Fig. 47
Fig. 48
SIT Top Convertible
SIT
SIT EN/EP
Fig. 49
Fig. 50
Fig. 51
Fig. 52
Fig. 53