Safety Information

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE.
IMPORTANT: 

Read all instructions and warnings carefully before starting installation.  Failure to 

follow these instructions may result in a possible fire hazard and will void the warranty.

Description

The BR/BC Series fireplaces are solid fuel, woodburning 
fireplaces. The BR36/42 (Builder Radiant) is a clean-face 
fireplace and the BC36/42 (Builder Circulating) unit has 
fixed grilles.

Precautions

CFM Corporation fireplaces and component parts have 
been highly tested and will operate safely when installed 
in accordance with instructions provided in this manual. 
Carefully read and understand all instructions 

before

 

beginning installation.
If you notice any damage to fireplace or component parts, 
immediately report damage to your Majestic Fireplaces 
dealer.
Only use CFM Corporation components or the warranty 
will be voided and a fire hazard may be created.
CFM Corporation warranty will be voided by and CFM 
Corporation disclaims any responsibility for the following 
actions:

• 

Installation of any damaged fireplace or chim-
ney component;

• 

Modification of fireplace, chimney assembly or 
any component parts thereof; 

(except for chase 

flashings as detailed in Chimney Top installation 
instructions).

• 

Installation other than as instructed by CFM 
Corporation; or

• 

Installation and/or use of any component part 
not manufactured or approved by CFM Corpo-
ration in combination or assembly with a Majes-
tic Fireplaces fireplace system, notwithstanding 
any independent testing laboratory or other 
third party approval of such component parts 
or accessory.

Any such action may possibly cause a fire hazard.

Consult local building codes to ensure that you are in 
compliance 

before 

installing the fireplace.

Fireplaces must be vented to the out-of-doors.

Do not obstruct or modify air inlets/outlets in any 
manner. 
Do not install combustible materials on any of the 
black fireplace surround.

Burn only solid wood fuel or gas logs.
Do not install a solid fuel burning insert or other 
products not specified for use with this fireplace.

Proposition 65 Warning: 

Fuels used in gas, wood-

burning or oil fired appliances, and the products of 
combustion of such fuels, contain chemicals known to 
the State of California to cause cancer, birth defects 
and other reproductive harm.
California Health & Safety Code Sec. 25249.6

Drafts

The fireplace should not be located in areas that create 
drafts (ie: frequently opened doors and central heating air 
inlets/outlets) that hamper the normal flow of air into the 
fire.

Gas Logs

If you plan to install a gas log, the gas line should be 
installed 

before

 framing the fireplace. The gas line must 

be installed by a certified gas line installer.

Safety Information . . . . . . . . . . . . . . . . . .  2
Specifications and Framing   . . . . . . . . . .  3
Parts Identification  . . . . . . . . . . . . . . . . .  5
Chimney Requirements  . . . . . . . . . . . . .  6
Planning Information . . . . . . . . . . . . . . . .  7
Installation   . . . . . . . . . . . . . . . . . . . . . . .  8
Replacement Parts . . . . . . . . . . . . . . . .  19
Accessories   . . . . . . . . . . . . . . . . . . . . .  20

Table of Contents

Units: 
FA30C1, FA30C0, FA30R1, FA30R0, GA30C1, GA30C0, 
GA30R1, GA30R0, FA40C1, FA40C0, FA40R1, FA40R0, 
GA40C1, GA40C0, GA40R1, GA40R0

Summary of Contents for Royalton BC36

Page 1: ...Woodburning Fireplace For Models BR36 BR42 BC36 BC42 DO NOT DISCARD THIS MANUAL Retain for future use 7412944 12 06 Rev 19 For use in U S Canada Underwriter s Laboratories Report No MH6018 Homeowner...

Page 2: ...se of any component part not manufactured or approved by CFM Corpo ration in combination or assembly with a Majes tic Fireplaces replace system notwithstanding any independent testing laboratory or ot...

Page 3: ...1041mm 8 Dia 203mm 8 2 2 m m If elbows are offset to the back of the unit chase depth will be 22 575mm Fig 2 BC36 Series speci cations and framing BC36 Series Woodburning Fireplace Circulating Model 1...

Page 4: ...Air Gas Line Access Electrical Access 1194mm 8 Dia 203mm 8 9 5 m m If elbows are offset to the back of the unit chase depth will be 22 575mm BR42 Series Woodburning Fireplace Fig 3 BR42 Series speci c...

Page 5: ...Collar Pan Flashing Draftstop Standoff Surround Damper Control Gas Line Knockout both sides Screen Grate Firebox Metal Safety Strips 1 2 or 3 pieces Outside Air Cover Plate Electrical Access Gas Line...

Page 6: ...42 Maximum 90 0 90 0 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbow to a structu...

Page 7: ...nning a chimney system it is important to know 1 The height of a chimney is measured from the hearth to the exit point on the termination 2 A chimney cannot be offset more than 30 from a vertical plan...

Page 8: ...location or how the chimney system should be run contact your Majes tic Fireplaces dealer for assistance If you live in a cold climate it is not required but highly recommended that you insulate repl...

Page 9: ...kit Remove knockout in the center of the back of the EB1 and install listed cable clamps Feed electrical wire through listed cable clamp leaving approximately 6 152 mm of wire exposed through the EB1...

Page 10: ...requirement at attic level Offset Installation In order to clear an obstruction it may be necessary to offset chimney from vertical This is accomplished by using CFM Corporation elbows Use the 30 Offs...

Page 11: ...ls strips provided with the replace Note Safety strips are not required over noncombusti ble oors where all supports at the base of the replace are noncombustible Four 4 nailing anges are supplied wit...

Page 12: ...de minimum required air space to chimney pipe for ceiling thickness up to 8 203mm When combined thickness of ceiling material ceiling joists and ooring material exceeds 8 203mm adjustments must be mad...

Page 13: ...additional ceilings repeat same steps required for rst ceiling installation See restop illus tration on Page 12 Figure 18 Penetrating the Roof Run pipe to roo ine Since chimney system must be vented...

Page 14: ...he wall with material of your choice Do not install a combustible mantel shelf less than 12 305mm from the top of the replace opening for radiant models and 12 305mm from top of grille opening for cir...

Page 15: ...2 305mm Min 1 38mm 6 159mm Min 12 305mm Max 12 305mm Min 1 38mm 6 159mm Min Mantel Clearance Radiant Model No Noncombustible Facing Material Combustible Mantel and Trim Finished Wall Header Standoff N...

Page 16: ...ecure the hearth extension to the oor to prevent shifting using trim molding or other similar means at three 3 outer edges Seal crack between the replace hearth and hearth extension with a noncombusti...

Page 17: ...inch Units of K BTU SQ FT HR F IN Thickness of Listed Material FP533ADD Addendum 6 1 99 djt 8 4 99 changed 2 to 1 one inch to 1 2 inch djt FP533ADD Fig 24 Hearth extension material factors FP550 Fig 2...

Page 18: ...ll chisel and hammer carefully tap around the knockout until it loosens and falls out Install 1 2 inch certi ed gas pipe through opening After gas pipe installation is complete use insulation that was...

Page 19: ...03 or 20007494 3032103 or 20007496 6b Firebrick Rear 3030102 or 20007495 3032102 or 20007497 6c Firebrick Rt Side 3030160 or 20007492 3030160 or 20007492 6d Firebrick Lt Side 3030104 or 20007493 30301...

Page 20: ...provided by the owner s insurance Accessories Contact your Majestic Fireplaces distributor or dealer for nishing Marble and Mantels available in a wide selection of styles Glass Door Standard Bi Fold...

Page 21: ...himney through CT100 a chase top Appropriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required Chase Top Housing Low pro le pyramid sty...

Page 22: ...ion Shield Used to prevent insulation from coming in AIS SK contact with the chimney system SK8 Chimney Sections Used to build chimney systems exposed above SK818CAN 1 Long roof SK84CAN 4 Long 45 Chim...

Page 23: ...s extended only to a Fireplace installed in the continental United States the state of Alaska and Canada only if and so long as the Fireplace is installed according to the installation instructions fu...

Page 24: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: