Determine offset distance of your chimney arrangement 
from centerline of fireplace to centerline of chimney 
where it is to pass through ceiling.
Locate center point of the chimney on ceiling as though 
a straight up chimney arrangement is to be used.  Mea-
sure your offset dimension from straight up chimney 
center point on ceiling.

Ceiling Chimney Hole/ 

Possible Obstructions

The size of the hole in ceiling will vary with the angle at 
which the chimney passes through ceiling. 
Drive a nail up through ceiling at marked chimney 
center point.  Go to floor above and see where hole 
will be cut.  Check to see where existing ceiling joists 
and other possible obstructions are located...i.e. wiring, 
plumbing etc... If necessary, re-position chimney and/or 
fireplace to avoid obstructions.

Cutting the Hole

Cover fireplace collar opening and cut proper sized 
chimney hole in chimney.  The SK8 pipe allows you to 
run pipe through a typical 16” on center joist without 
cutting joists.

Framing the Ceiling Hole

Frame the ceiling chimney hole as shown in Figure 
12.  It is good practice to use framing lumber that is the 
same size as the ceiling joists; this is a requirement at 
attic level.

Offset Installation

In order to clear an obstruction, it may be necessary 
to offset chimney from vertical. This is accomplished 
by using CFM Corporation elbows. Use the 

30° Offset 

Elbow

 table on Page 6 to determine proper offset and 

parts required.
Each offset requires two (2) elbows. The second elbow 
is equipped with support straps. It is very important to 
install the second elbow in each offset as close to the 
ceiling or support as possible so that the elbow straps 
can be secured to framing members to help support the 
weight of the chimney.

Straight-Up Chimney Installation

To mark the centerline of the flue, put the fireplace 
in final position and measure out from the wall: 8

¹⁄₄

"       

(210 mm)
Mark a spot on the ceiling directly above the fireplace. 
Draw a line parallel to the back wall through this mark. 
(Fig. 11)
Using a plumb bob positioned directly over center point 
of fireplace flue collar, mark the ceiling to establish the 
chimney center point. (Fig. 11)

FP556

BR/BC 

LOCATE CENTER LINE

11/10/97

����

(210mm)

FP556

Fig. 11 

 Locate centerline of chimney with plumb line.

Chimney Centerline

Actual Centerpoint

Plumb Line

Plumb Bob

Imaginary 

Centerpoint

Fig. 12 

 Typical frame for ceiling chimney hole.

FP551

FP551

BR/BC

9/29/97

AB

AB

A

  "SK" Series framing = 14

¹⁄₂

" X 14

¹⁄₂

" (368 x 368mm)

B

  "S" Series framing = 17

¹⁄₂

" X 17

¹⁄₂

"  (445 x 445mm)

Existing Ceiling 

Joists

Ceiling

New Framing 

Members

Chimney 

Hole

Summary of Contents for Royalton BC36

Page 1: ...Woodburning Fireplace For Models BR36 BR42 BC36 BC42 DO NOT DISCARD THIS MANUAL Retain for future use 7412944 12 06 Rev 19 For use in U S Canada Underwriter s Laboratories Report No MH6018 Homeowner...

Page 2: ...se of any component part not manufactured or approved by CFM Corpo ration in combination or assembly with a Majes tic Fireplaces replace system notwithstanding any independent testing laboratory or ot...

Page 3: ...1041mm 8 Dia 203mm 8 2 2 m m If elbows are offset to the back of the unit chase depth will be 22 575mm Fig 2 BC36 Series speci cations and framing BC36 Series Woodburning Fireplace Circulating Model 1...

Page 4: ...Air Gas Line Access Electrical Access 1194mm 8 Dia 203mm 8 9 5 m m If elbows are offset to the back of the unit chase depth will be 22 575mm BR42 Series Woodburning Fireplace Fig 3 BR42 Series speci c...

Page 5: ...Collar Pan Flashing Draftstop Standoff Surround Damper Control Gas Line Knockout both sides Screen Grate Firebox Metal Safety Strips 1 2 or 3 pieces Outside Air Cover Plate Electrical Access Gas Line...

Page 6: ...42 Maximum 90 0 90 0 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbow to a structu...

Page 7: ...nning a chimney system it is important to know 1 The height of a chimney is measured from the hearth to the exit point on the termination 2 A chimney cannot be offset more than 30 from a vertical plan...

Page 8: ...location or how the chimney system should be run contact your Majes tic Fireplaces dealer for assistance If you live in a cold climate it is not required but highly recommended that you insulate repl...

Page 9: ...kit Remove knockout in the center of the back of the EB1 and install listed cable clamps Feed electrical wire through listed cable clamp leaving approximately 6 152 mm of wire exposed through the EB1...

Page 10: ...requirement at attic level Offset Installation In order to clear an obstruction it may be necessary to offset chimney from vertical This is accomplished by using CFM Corporation elbows Use the 30 Offs...

Page 11: ...ls strips provided with the replace Note Safety strips are not required over noncombusti ble oors where all supports at the base of the replace are noncombustible Four 4 nailing anges are supplied wit...

Page 12: ...de minimum required air space to chimney pipe for ceiling thickness up to 8 203mm When combined thickness of ceiling material ceiling joists and ooring material exceeds 8 203mm adjustments must be mad...

Page 13: ...additional ceilings repeat same steps required for rst ceiling installation See restop illus tration on Page 12 Figure 18 Penetrating the Roof Run pipe to roo ine Since chimney system must be vented...

Page 14: ...he wall with material of your choice Do not install a combustible mantel shelf less than 12 305mm from the top of the replace opening for radiant models and 12 305mm from top of grille opening for cir...

Page 15: ...2 305mm Min 1 38mm 6 159mm Min 12 305mm Max 12 305mm Min 1 38mm 6 159mm Min Mantel Clearance Radiant Model No Noncombustible Facing Material Combustible Mantel and Trim Finished Wall Header Standoff N...

Page 16: ...ecure the hearth extension to the oor to prevent shifting using trim molding or other similar means at three 3 outer edges Seal crack between the replace hearth and hearth extension with a noncombusti...

Page 17: ...inch Units of K BTU SQ FT HR F IN Thickness of Listed Material FP533ADD Addendum 6 1 99 djt 8 4 99 changed 2 to 1 one inch to 1 2 inch djt FP533ADD Fig 24 Hearth extension material factors FP550 Fig 2...

Page 18: ...ll chisel and hammer carefully tap around the knockout until it loosens and falls out Install 1 2 inch certi ed gas pipe through opening After gas pipe installation is complete use insulation that was...

Page 19: ...03 or 20007494 3032103 or 20007496 6b Firebrick Rear 3030102 or 20007495 3032102 or 20007497 6c Firebrick Rt Side 3030160 or 20007492 3030160 or 20007492 6d Firebrick Lt Side 3030104 or 20007493 30301...

Page 20: ...provided by the owner s insurance Accessories Contact your Majestic Fireplaces distributor or dealer for nishing Marble and Mantels available in a wide selection of styles Glass Door Standard Bi Fold...

Page 21: ...himney through CT100 a chase top Appropriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required Chase Top Housing Low pro le pyramid sty...

Page 22: ...ion Shield Used to prevent insulation from coming in AIS SK contact with the chimney system SK8 Chimney Sections Used to build chimney systems exposed above SK818CAN 1 Long roof SK84CAN 4 Long 45 Chim...

Page 23: ...s extended only to a Fireplace installed in the continental United States the state of Alaska and Canada only if and so long as the Fireplace is installed according to the installation instructions fu...

Page 24: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: