MP2600D, MP2600C & MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information
Page
42
of
52
Connecting power supply:
Put power supply switch to OFF, and then connect one side of power
supply cable to the entry of back panel of router, and another side to
power supply jack
(
AC: 220V 50Hz/60Hz, DC: -48V
)
, only MP1700E
supports
Put power supply switch to ON
Check whether the power supply lamp of front panel is on, if not,
please repeat step one and two.
Main Control Board Cable Connection
The section explains the method of connecting
MP2600D/MP2600C/MP1700E router control board cable to network
including connecting router console port.
Console Port Connection
Routers provide one EIA/TIA-232 async serial console port. The user
configures router via the port by adopting RS-232 serial character terminal
(normally a PC).
Step 1: Find a character terminal – a standard terminal
with RS-232
serial or normal PC.
Step 2: Ensure that router or terminal is out of power supply and
connect RS-232 serial and console port with cables.
Grounding Wire Connection
MP2600D/MP2600C/MP1700E connecting to the ground guarantees of
anti-thunder and malfunctioning of routers. For external network
connection, such as E1 interface, PSTN are protected by the grounding
cable.
Connect this point and ground by a thick cable, with the resistance no
bigger than 4
Ω
. If the router is installed on 19-inch standard rack, the
rack should be grounding.