1 S A E M o d u l e C a b l e C o n n e c t i o n
Step 1: Insert one side of DB-25 to 1SAE module DB-25 interface and
screw down fixed knob.
Step 2: Connect another DB25 interface to V.24-V.35 (DB-25, M-34)
cable and then connect the following equipment:
-
If WAN is DDN line, connect (V.35 cable) to digital Modem V.35
interface.
-
If WAN is dialup line, connect (V.24 cable) to analog Modem serial.
Step 3: After power on, check indicator status on 1SA module panel.
-
DCD on: Link connected
1CE1/1E1 Module Cable Connection
Step 1: Connect one side of BNC plug to BNC interface of 1CE1/E1
module. Connect another side to equipment. Connect TX to RX
equipment. Connect RX TX line.
Step 2: After power on, check LOS status of 1CE1/E1 module.
Indicator on means malfunction and signal loses sync. Then check the
line.
1M336 Module Cable Connection
Insert RJ11 plug of 1M336 module cable to LINE jack.