Electrical connection
DANGER
Danger to life from electric
shock
Switch the mains fuse off.
CAUTION
Unit damage in the case of
short-circuits
Cut off and insulate any
unnecessary cable cores.
CAUTION
Danger of short-circuits
through incorrect feeding of
the power cable into the
housing.
Feed the power cable
professionally through the
cable grommet and make sure
there is tension relief. See
printed cable run.
Locate both cable grommets [5] in the
connecting flange.
Feed the power cable through the open
cable grommet.
Connect the power cable to the connection
terminal socket [9] as shown in the wiring
diagram on Page 25.
Internal housing installation
see also Figure A, bottom right
CAUTION
Danger of short-circuits and
unit damage with wrong
polarity
Make sure the polarity is
correct, see labels A and B.
NOTICE
Damage to the contact holder
caused by tearing or pulling
on the plug cable
Always hold the internal
housing near the connecting
flange to avoid pulling tension
at plug connection.
Plug the connection terminal plug [12] on to
the connection terminal socket [9].
Push the internal housing parallel onto the
connecting flange as shown bottom right in
Figure A.
The internal housing must clip into
the upper locking hooks [3.1].
Don’t trap the cables.
Close both catches [13] with a screwdriver.
Switch the mains fuse on.
Carry out a function test.