9. CALIBRATION OF THE
WEIGHING CELL
Carried out when set weight differs from actual
ground weight
Step 1
Connect the grinder to the power supply and
switch on the grinder using the switch aside.
Display grinder „ON“
Power switch
Step 2
Hold the „Start / Stop button for 3 sec, the
grinder restarts (Pic 1). Hold the buttons 1 and 2
at once while the grinder restats (Pic 2).
Pic 1
Pic 2
Step 3
The display shows a value between 310 - 350
(Pic 3). Press 1 afterwards again, the display
shows „Cal“ shortly followed by „200“ (Pic 4).