Diagnostic Manual ( EMS)
LCV MDI BSIII CRDe
Rev 01- Mar 14
All copyrights reserved by
The repair methods given by the manufacturer in this document are based on the technical specifications current at the time of release.
The methods may be modified as a result of changes introduced by the manufacturer in the production of the various component units
and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of whole of the present
document, are prohibited without the prior written consent of 2014 Mahindra & Mahindra Ltd (Truck & Bus Division)
Battery voltage signal: ( Vext 1 & Vext 2)
DTC
Diagnostic item
P0642
P0643
P1641
P0652
P0653
P1651
Sensor Supply voltage falls below the calibrated value.
Sensor Supply voltage exceeds the calibrated value.
Analogue to Digital Convertor Fault.
Sensor Supply voltage falls below the calibrated value.
Sensor Supply voltage exceeds the
calibrated value.
Analogue to Digital Convertor Fault.
TO CHECK
TO RECTIFY
1.Sensor connection supplied by ECU (Cam
& Pedal track2)
1.Check individual correction and
connect
2.Apply Diagonastic charts of respective
sensors
2. Remove and connect again.
3.Terminal backout, wire open
circuit & short circuit.
4.Connect properly
5.Change sensor
P0642
P0643
P1641
P0652
P0653
P1651
Summary of Contents for Cosmo
Page 55: ......