Battery voltage signal:
DTC
Diagnostic item
P0562
P0563
P1560
Battery Voltage falls below 6 volts
Battery Voltage falls below 18 volts.
A-D Convertor Fault.
TO CHECK
TO RECTIFY
1. Battery and ECU connections
1. Connect properly
2.Resistance between chassis & ECU
ground
2. Fix ECU & Battery ground firmly
3. Battery charge circuit (Insulation on
battery positive cable)(Alternator circuit)
3. Change battery positive cable
4. Battery voltage at key on (min 9 V)
(Min voltage for ECU is 6 volts - considering
2.5 Volts reduction during cranking)
4. Change battery