background image

 

                                                                                   

                                                              Adam Equipment 2011 © 

 

Adam Equipment 

 

 

 

 

PTS SERIES

   

With AE402 Indicator 

 

 

(P.N. 3106610715, Revision E, April 2011) 

 

Summary of Contents for PTS 2000

Page 1: ...Adam Equipment 2011 Adam Equipment PTS SERIES With AE402 Indicator P N 3106610715 Revision E April 2011 ...

Page 2: ...Adam Equipment 2011 ...

Page 3: ...our safety and correct operation please read the following instructions carefully before using it CONTENT 1 0 SAFETY 3 2 0 INSTRUCTION 5 2 1 SPECIFICATIONS 5 2 2 PACKING LIST 5 3 0 INSTALLATION 8 3 1 AE 402 ASSEMBLY 10 4 0 CALIBRATION 13 5 0 TROUBLE SHOOTING 14 6 0 MAINTENANCE 15 ...

Page 4: ...2 Adam Equipment 2011 ...

Page 5: ...allet truck must be operated by trained personnel only Check the pallet truck first before using it making sure that the wheels handles and forks are fitted correctly and secure Avoid unsuitable and uneven floor surfaces Please wear protective clothing where necessary Allow 60cm clearance from the pallet truck when operating Pay attention and focus on the object you are lifting Do not overload ...

Page 6: ...4 Adam Equipment 2011 ...

Page 7: ...ight 125 kg 275 Lb 135 kg 297 Lb See the User Manual for the Indicator supplied with the PTS for more information about the weighing features and operation 2 2 PACKING LIST Part No Part name QTY 3101410695 Indicator mounting bracket upper 1 301177255 M4 x 6 SS Soc Head cap Screw din912 A2 4 3106610715 PTS Manual Instructions 1 3101010700 M4 Allen key 1 3101710929 Roller pin φ 20 x 86 1 3101710930 ...

Page 8: ...6 Adam Equipment 2011 ...

Page 9: ...7 Adam Equipment 2011 ...

Page 10: ...e down fully until completing the instructions below 1 Insert the roller pin into the hole of roller rack securing the handle to the frame 2 Fit the split pin through the holes provided 3 Pass the chain through the center hole of the roller pin Secure the end of the chain to the slot on the end of the unloading plate 4 Remove the transit rod before use Press the handle down only far enough to rele...

Page 11: ...9 Adam Equipment 2011 ...

Page 12: ...10 Adam Equipment 2011 3 1 AE 402 ASSEMBLY Rear view of AE 402 Indicator Fit the PTS to Indicator cable as shown in the picture below 5 pin connector fitted here ...

Page 13: ... using 4 x M4 screws as the picture below shows these should be tightened using the Allen Key supplied The Indicator cable goes through the hole on the bracket and connects to the Indicator using the 7 pin connector M4 x 6 Screws 4 places 7 pin connector fitted here ...

Page 14: ...12 Adam Equipment 2011 The AE 402 indicator is placed into the mounting bracket and secured using the two plastic fasteners as shown below Plastic fasteners used to secure Indicator to the bracket ...

Page 15: ...13 Adam Equipment 2011 4 0 CALIBRATION The PTS is factory calibrated please refer to the user manual for the indicator supplied AE 402 when further calibration when required ...

Page 16: ... be raised No hydraulic oil Oil is not clean Refill oil chamber See Figure 1 Change oil 3 Forks can not descend Position of the goods are to one side of the truck Relocate load 4 Oil spillage Aging or damaged seals Call for Service 5 Forks descend when the trigger is not in descend position The oil could be unclean Some parts of the hydraulic system are damaged Change the oil Vent the air Call for...

Page 17: ...ult in the forks not raising when first used Please move the handle up and down several times to allow air to escape Routine maintenance is necessary You should focus on the wheels and handle assemblies When the truck is not in use remove the items on the forks and reset the forks to their lowest position All the bearings and axles have been lubricated please check at regular intervals ...

Page 18: ...ckaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and r...

Page 19: ...to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by A...

Page 20: ...ve software features including parts counting percent weighing etc Crane scales for heavy duty industrial weighing Digital Electronic Scales for Medical use Retail Scales for Price computing Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reser...

Reviews: