20
MMS 2000P
MMS 2400
MMS 3000
EN
4.3.5. MENU
For enhanced adjustment is available MENU function.
List of MENU parameters
Par.
Nr
Displayed
Name
Description
Min.
Max. Step Unit MIG
Pulse
MIG
Double
Pulse
MIG MMA TIG
11
Arc
Arc length trimming
-30,0
30,0
1
%
X
X
X
-
-
12
GPr
Gas pre-flow time
0,0
10,0
0,1
sec
X
X
X
-
-
13
GPo
Gas post-flow time
0,0
10,0
0,1
sec
X
X
X
-
-
14
cSS
Creep start speed
1,5
22,0
0,1 m/min
X
X
X
-
-
15
hSL
Hot-start level
100
199
1
%
X
X
X
X
-
16
cFL
Crater-fill level
1
100
1
%
X
X
X
-
-
17
hSt
Hot-start time
0,0
10,0
0,1
sec
X/-
X/-
X/-
X
-
18
cFt
Crater-fill time
0,0
10,0
0,1
sec
X/-
X/-
X/-
-
-
19
Act
Active time for interval weld.
0
10
0.1
sec
X
X
-
- -
20
PAU
Pause time for interval weld.
0
10
0.1
sec
X
X
-
- -
21
L
Inductance trimming
-9,0
9,0
1
-
X
-
-
-
-
22
EPL
End pulse voltage
10,0
50,0
0,1
V
X
-
-
-
-
23
EPt
End pulse time
1
100
1
msec
X
-
-
-
-
24
bbt
Burn-back time
10
250
1
msec
X
X
X
-
-
31
PF
Pulse frequency
10
500
1
Hz
-
X
X
-
-
32
PL
Pulse length
0,10
3,50
0,05 msec
-
X
X
-
-
33
Prr
Peak rise rate
1
10
1
-
-
X
X
-
-
34
PFr
Peak fall rate
1
10
1
-
-
X
X
-
-
35
bcL
Base current level
10
500
1
A
-
X
X
-
-
36
FcL
Fall current level
10
500
1
A
-
X
X
-
-
41
dPF
Double pulse frequency
0,5
5
0,1
Hz
-
-
X
-
-
42
dPA
Double pulse amplitude
5
95
1
%
-
-
X
-
-
61
cLc
Cable length compensation
0,0
25,0
0,1
m
X
X
X
-
-
62
CoL
Water cooling unit installed
No
Yes
-
-
X
X
X
-
X
MENU