Pos: 66 / Technische Dokumentation/Alle Geräte/Überschriften/ Überschriften 1.1/B/ Überschrift 1.1: Bed ienung der Achs traverse AT-N B @ 29\m od_1339756090988_ 75.docx @ 1608679 @ 2 @ 1
5.2
Operating the Axle Crossbar AT-NB (Asymmetrical Load Center)
Pos: 67 / Technische Dokumentation/Hebetechnik/PITFORCE/551101 A B / A BA / ABT / AT-N B / A TV / SA T/BA/Inhalt: 5511 Bed ienung N iederflurtraverse AT-N B ( Tex t) @ 29\m od_1339756390082_ 75.d ocx @ 1608723 @ @ 1
•
The general operating instructions for load accessories must be observed.
•
Pre-position actuators central to the crossbar at the lifting points.
•
Pre-position the lifting accessory central to the load’s centre of gravity.
•
If necessary, identify the centre of gravity again in the case of asymmetry or
change. To do this, briefly raise the load slowly, watch out for tilting; if neces-
sary, lower slowly and reposition the lifting accessory at the tilted side.
•
Always take up the load securely, without risk of slipping and central to the cen-
tre of gravity.
Pos: 68 / Technische Dokumentation/Hebetechnik/PITFORCE/551101 A B / A BA / ABT / AT-N B / A TV / SA T/BA/Inhalt: 5511 Bed ienung N iederflurtraverse AT-N B ( Bilder) @ 24\m od_1310627728678_0.docx @ 1023747 @ @ 1
Pos: 69 /----- Format-----/MAN UELLER UM BRUCH Seitenumbruch @ 0\m od_1134403577687_ 0.docx @ 1277 @ @ 1