NDB-15-50 IM 28 FEB 2018
© 2018 NOVATEC, Inc. All Rights Reserved
Page 8
7.0 TEMPERATURE CONTROLLER
RKC Brand, Model: RF-100, NOVATEC Part Number: 02275 (Replaces RKC Rex C-100)
7.1 Overview
7.2 Initial Settings
•
To enter Engineering mode: Press RUN/STOP key for more than 2 seconds to change from
RUN to STOP, STOP lamp turns on.
•
Press & hold SET & RUN/STOP simultaneously until F00 displays.
•
Continue to press SET until MODE displays. Change MODE setting to 0128, this allows
access to engineering parameters above F09.
•
Press SET until F00 displays, press UP/DOWN arrow keys until Function Block to be
accessed appears.
•
Press SET to scroll through parameters of each function block.
•
Press UP/DOWN arrow keys to change values than return to Function Block.
•
Press UP/DOWN Arrow keys to move to next Function Block.
•
After parameters have been changed, return to F00 change MODE setting back to 0.
•
Exit Engineering mode the same way it was entered.
•
Press RUN/STOP key for more than 2 seconds to change from STOP to RUN, STOP lamp
turns off.