© 2011 Novatec Inc. All Rights Reserved
10
AL-1 IM 10-20-2011
Al-1 Compressed Air Loader Instructions
MAINTENANCE
The filter element should be cleaned periodically by vacuuming or back flushing it with compressed
air.
TROUBLESHOOTING
If the AL-1 compressed air loader is not functioning correctly, the following items should be checked:
1.
Check the filter. If the filter is dirty, it should be cleaned using a vacuum cleaner or compressed air.
If the filter is still dirty after cleaning or is damaged, the filter element should be replaced.
2.
Ensure that all supply lines are connected. Check the power cord, compressed air supply, and the
twist lock plugs for proper operation.
3.
Check the solenoid for proper operation.
4.
Ensure all adjustable points are set correctly. Check the photoelectric sensor, regulator gauge, and
the air amplifier index for correct settings.
5.
Check the entire system for leaks. Reconnect any material or compressed air lines, and replace any
gasket or sealant as necessary.
6.
Check that the air amplifier index mark is set at 6.