Al-1 Compressed Air Loader Instructions

 

 

OPERATION 

 
To begin operation, simply plug the power cord into a 115-volt outlet, turn on the compressed air 
supply and adjust the regulator gauge to 60 PSI. This setting should provide a relatively good flow for 
any material.  The only adjustment that is needed once the unit is in operation is fine tuning the material 
flow rate, using the filter/regulator with gauge if necessary.  To disable the unit, simply unplug it.    
 
Once in operation, fine-tune the adjustment until a smooth, consistent flow is obtained considering the 
material characteristics, the distance from your material source and the ability of the system to easily 
pickup and begin moving the material. If an adjustable pick-up device is being used, make sure the 
device is set at the position where a smooth flow of material can be obtained. 
 
Pull the knob on the regulator to adjust the compressed air setting. Turn the knob clockwise to increase 
the pressure and counter-clockwise to decrease the pressure.  Once the desired level is obtained, lock 
the knob back in the place by pushing it down. 
 
Observe the operation to assure it is consistent and responsive and that all components of the 
installation are tight, dust free and secure. 
 
 
 

Summary of Contents for Novatec AL-1

Page 1: ...COMPRESSED AIR LOADER MODEL AL 1 Document AL 1 IM 10 22 2011...

Page 2: ...er Instructions TABLE OF CONTENTS Important Notices and Precautions 3 Quick Installation 4 Product Description 4 Principle of Operation 5 Unpacking and Inspection 5 Photoelectric Sensor Diagram 6 Inst...

Page 3: ...Do not operate unless this instruction manual is completely understood WARNING Disconnect power and compressed air before servicing equipment Only qualified technicians should service equipment CAUTIO...

Page 4: ...ng hoppers or directly to process machines using compressed air The AL 1 is shipped complete ready for quick set up and use Novatec compressed air loaders only require a 14 0 SCFM 40 PSIG compressed a...

Page 5: ...ed again once the material level drops This process ensures a steady consistent level of material The loading operation is generated by a solenoid valve which operates in response to the photoelectric...

Page 6: ...2011 Novatec Inc All Rights Reserved 6 AL 1 IM 10 20 2011 Al 1 Compressed Air Loader Instructions FIGURE 1 PHOTOELECTRIC SENSOR DIAGRAM...

Page 7: ...ionally tighten down the filter hold down knob and make sure the clamping ring holding the filter is secure CAUTION Do not over tighten the filter hold down knob excessive torque could damage the filt...

Page 8: ...ilter regulator with gauge assembly must interconnect with a 115 volt supply outlet the twist lock plug connection for the photoelectric sensor the air amplifier for its compressed air connection the...

Page 9: ...he adjustment until a smooth consistent flow is obtained considering the material characteristics the distance from your material source and the ability of the system to easily pickup and begin moving...

Page 10: ...or compressed air If the filter is still dirty after cleaning or is damaged the filter element should be replaced 2 Ensure that all supply lines are connected Check the power cord compressed air suppl...

Page 11: ...lamp 1 50 OD 50049 Clamping Ring 6 88 diameter 08883 Filter regulator with gauge 08992 Cartridge Filter 07978 Silicone Gasket 2 05 OD 08891 Vacuum Hose 1 50 OD 50003 Knob filter hold down 08887 Knob p...

Page 12: ...rranty contained here Non payment of invoice beyond 90 days will invalidate the warranty A renewed warranty can be purchased directly from Novatec Please note that we always strive to satisfy our cust...

Reviews: