© 2011 Novatec Inc. All Rights Reserved
9
AL-1 IM 10-20-2011
Al-1 Compressed Air Loader Instructions
OPERATION
To begin operation, simply plug the power cord into a 115-volt outlet, turn on the compressed air
supply and adjust the regulator gauge to 60 PSI. This setting should provide a relatively good flow for
any material. The only adjustment that is needed once the unit is in operation is fine tuning the material
flow rate, using the filter/regulator with gauge if necessary. To disable the unit, simply unplug it.
Once in operation, fine-tune the adjustment until a smooth, consistent flow is obtained considering the
material characteristics, the distance from your material source and the ability of the system to easily
pickup and begin moving the material. If an adjustable pick-up device is being used, make sure the
device is set at the position where a smooth flow of material can be obtained.
Pull the knob on the regulator to adjust the compressed air setting. Turn the knob clockwise to increase
the pressure and counter-clockwise to decrease the pressure. Once the desired level is obtained, lock
the knob back in the place by pushing it down.
Observe the operation to assure it is consistent and responsive and that all components of the
installation are tight, dust free and secure.