9 - Properties
eDynamo| Secure Card Reader Authenticator | Programmer’s Manual (COMMANDS)
Page 157 of 245 (
D998200115-17
)
9.24
Property 0x6D - EMV Contact Notification Configuration (Contact Only)
Property ID:
0x6D
Property Type: Byte
Length: 1 byte
Get Property: Yes
Set Property:
Yes
Default Value: 0x02 (Card Removed)
The host uses this property to enable or disable specific EMV notification messages the device sends with
Notification 0x0300 - Transaction Status / Progress Information
. Setting a bit to 1 enables the
specified notification message, and setting a bit to 0 disables it.
The following table defines each bit in the property and describles which notification message it controls.
EMV Notification Enable: (Bit 0 is the least significant bit)
Bit
Field Name
Description
0
Card Inserted
When an EMV transaction is not in progress, this setting controls whether the
device sends
Notification 0x0300 - Transaction Status / Progress
0x01 = Card Inserted
when a
cardholder inserts a card into the EMV card slot.
When an EMV transacation is in progress, insertion notifications are controlled
using the Reporting Option field in
Extended Command 0x0300 - Initiate
1
Card Removed
Controls whether the device sends
Notification 0x0300 - Transaction Status /
message with its event field set to
0x08 = Card
Removed
when the cardholder removes a card from the EMV card slot.
2-7
Reserved
Always set to zeroes.
For eDynamo, this property is available in firmware revisions 1000003354E00 (released June 2017) and
later.
For mDynamo, this property is available in firmware revisions 1000003358C00 (released in June 2017)
and later.
This property is stored in non-volatile memory, so it persists when the device is power cycled. When this
property is changed, the device must be reset (see
) or powered off for at
least 30 seconds, then powered on, before the changes will take effect.
Example Set Request (Hex)
Cmd Num
Data Len
Property ID
Data
01
02
6D
02
Example Set Response (Hex)
Result Code
Data Len
Data
00
00