![Magnuson Superchargers Magnum DI Installation Instructions Manual Download Page 59](http://html1.mh-extra.com/html/magnuson-superchargers/magnum-di/magnum-di_installation-instructions-manual_694649059.webp)
216. Connect the 90° hose assembly from the last
step to the upper LTR spigot with a provided
spring clamp (shown with an arrow). This
will go through the 1.5” hole that was drilled
earlier.
217. Replace the OEM bolt on the EVAP solenoid
with the provided M6 x 25 mm bolt shown with
the green washer in this image.
218. Apply a light coat of Lubriplate grease to the
O-ring on the EVAP solenoid.
219. Install the EVAP solenoid in the location
Install the EVAP solenoid in the location
shown and torque to 106 in-lbs
shown and torque to 106 in-lbs
. Also plug
in the electrical connection to the EVAP
solenoid.
2016-2020 LT1 Chevrolet Camaro
9/17
59