Method 2 (see
fi
gure 2-6): When the AC and DC service panels are near each other, then the AC
Grounding Electrode Conductor (GEC – AC) and DC Grounding Electrode Conductor (GEC – DC)
can be connected to a single Grounding Electrode. In this method - since there are multiple con-
nections to the DC Grounding Electrode (GEC – DC) - the size of the DC Grounding Electrode
Conductor can not be smaller than the largest conductor in the DC system (usually the battery-
to-inverter cable).
Figure 2-6, Multiple Connections to DC Ground Rod (Method 2)
Figure 2-7, Single Connection to DC Ground Rod (Method 3)
Method 3 (see
fi
gure 2-7): The AC Grounding Electrode Conductor (GEC – AC) is bonded to the
DC ground point and the DC Grounding Electrode Conductor (GEC – DC) is the
only connection
to
the Grounding Electrode, which must be a rod, pipe, or plate electrode.
In this method, since there is only one connection to the ground rod, the DC Grounding Electrode
Conductor is not required to be larger than #6 AWG (13 mm
2
) copper. The reasoning for allowing
this smaller grounding electrode conductor is that it is only required to stabilize the system volt-
age with respect to earth and the other properly-sized conductors in each electrical system will
safely carry any fault currents if they occur.
Installation
A C
D C S e rvice
P a n e l
A C S e rvice
P a n e l
D C E lec tric al S y s tem
A C E lec tric al S y s tem
N eutral
Positive
N egative
D C
G rounding
S y s tem
N e g a tive
S B J
GC
GE
GE C -A C
E GC - A C
AC Ground
D C Ground
S B J
E GC - D C
GC
N e u tra l
H ot
GE C -D C
GB B
GB B
Grounding Electrode
(AC and D C sides shared)
M S -P A E S eries Inv erter/ C harger
A C
D C S e rvice
P a n e l
A C S e rvice
P a n e l
D C E lec tric al S y s tem
A C E lec tric al S y s tem
N eutral
Positive
N egative
D C
G rounding
S y s tem
N e g a tive
S B J
GC
GE C -A C
E GC - A C
AC Ground
D C Ground
S B J
E GC - D C
GC
N e u tra l
H ot
GE C -D C
GE
GB B
GB B
Grounding Electrode
(D C side dedicated)
M S -P A E S eries Inv erter/ C harger