2017 Sensata Technologies
Page 42
Appendix A – Specifi cations and Optional Equipment
Appendix A – Specifi cations and Optional Equipment
A-1 Inverter/Charger
Specifi cations
Models
ME2012 (-15B, -20B)
ME2512
ME3112
Inverter Specifi cations
Input Battery Voltage Range
9 to 16 VDC
9 to 16 VDC
9 to 16 VDC
Absolute Maximum DC Input
25 VDC
25 VDC
25 VDC
AC Output Voltage Accuracy
120 VAC ±5% (
≤
continuous power)
Output Frequency and Accuracy
60 Hz ± 0.1 Hz
Continuous Power Output (@ 45°C)
2000 VA
2500 VA
3100 VA
Continuous AC Output Current
17 A
21A
26 A
1 msec Surge Current (AAC)
60
100
120
100 msec Surge Current (AAC)
37
45
50
5 sec Surge Power (real watts)
3700
5000
6000
30 sec Surge Power (real watts)
3450
4500
4800
5 min Surge Power (real watts)
3100
3500
3950
30 min Surge Power (real watts)
2400
2900
3500
Rated Input Battery Current
266 ADC
333 ADC
413 ADC
Inverter Ef
fi
ciency (peak)
95%
91%
90%
HBCO/HBCI
≥
15.8 VDC
LBCO/LBCI
9.0 VDC (adj)/12.5 VDC
Series Stacking 120/240 VAC
No
Transfer Time
16 msecs
Search Mode (typical)
5 watts
No Load (120 VAC output, typical)
20 watts
23 watts
25 watts
Waveform
Modi
fi
ed Sine Wave
Charger Specifi cations
Continuous Output at 45°C
100 ADC
120 ADC
160 ADC
Input Current - Rated Output (AAC)
15
18
22
Charger Ef
fi
ciency
85%
AC Input Frequency Range
50 to 70 Hz
AC Input Voltage Range
60 to 140 VAC (120 VAC nominal)
Power Factor
> 0.95
General Features and Capabilities
Transfer Relay Capability
Two input legs at 30 amps each, or combine for 60 amps*
Five-stage Charging Capability
Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™
Battery Temp Compensation
Yes, 15 ft Battery Temp Sensor standard
Internal Cooling
0 to 120 cfm variable speed drive using dual 92 mm brushless DC fan
Overcurrent Protection
Yes, with two overlapping circuits
Over-temperature Protection
Yes, on transformer, MOSFETS, and battery
Corrosion Protection
PCB’s conformal coated, powder coated chassis/top, and stainless steel fasteners
Safety Listings
ETL listed to UL/cUL 458, and CSA C22.2 # 107.1-01
Warranty
3 years parts and labor
Dual Branch-Rated Output Breakers
Optional on ME2012 (15 or 20-amp breakers)
Environmental Specifi cations
Operating Temperature
-20°C to +60°C (-4°F to 140°F)
Non-operating Temperature
-40°C to +70°C (-40°F to 158°F)
Operating Humidity
0 to 95% RH non-condensing
Physical Specifi cations
Unit Dimensions (h x w x d)
13.75” x 12.65” x 8.0” (34.9 cm x 32.1 cm x 20.3 cm)
Shipping Dimensions (h x w x d)
19” x 15” x 13” (48.3 cm x 38.1 cm x 33 cm)
Mounting
Shelf (top or bottom up) or wall (no uncovered vents on top or bottom)
Unit Weight
37 lb (16.8 kg)
41 lb (18.6 kg)
46 lb (20.9 kg)
Shipping Weight
46 lb (20.9 kg)
51 lb (23.1 kg)
56 lb (25.4 kg)
Max operating altitude
15,000’ (4570 m)
Speci
fi
cations @ 25°C (unless otherwise noted) - Subject to change without notice.
* The pass-thru capability on each leg of the -15B and -20B models is limited by the output breaker size on each output.