©2013 Magnum Energy, Inc.
35
5.0 Operation
LED
Status
Meaning
INV
(green)
OFF
1. Inverter is disabled; or 2. Remote is in Power
Saver mode – press any button to activate LEDs.
ON
Inverter is enabled – 1. Supplying AC power on
the output; or 2. In Standby (a charge status
displays); the inverter will automatically supply
AC power to the loads if shore or generator
power is lost.
BLINKING
Inverter is in Search mode (the AC load is below
the
Search Watts
setting).
FAULT
(red)
OFF
Normal operation.
ON
A fault condition has been detected, check the
LCD display to
fi
nd and correct the cause.
5.3.4 LED Indicator Guide
The remote provides the following LED statuses. Use them along with the LCD
display to determine the inverter/charger’s operating status.
Table 5-1, LED Indicator Guide
IntRelay
appears on the LCD and
the FAULT (red) LED is on. The INV
(green) LED is off.
FAULT !
IntRelay
Figure 5-37, Internal Relay Fault
• Internal
Relay
Fault
– The internal transfer relay is not closing even
though the inverter is in Charge mode. Contact Magnum Technical Support
(425-353-8833) for assistance.