![Magnum Energy ME-MR Owner'S Manual Download Page 21](http://html1.mh-extra.com/html/magnum-energy/me-mr/me-mr_owners-manual_3619347021.webp)
©2013 Magnum Energy, Inc.
15
3.0 Setup
3.2.10 Charger Standby Menu
• CHARGER
–
Select whether to activate Charger Standby mode after
AC power is connected (charger ready and waiting for AC input).
Default setting:
CHARGER = No AC In
Range: No AC In, Chg Stby
What is Charger Standby?
When the charger is in Charger Standby, the
incoming AC is still available on the inverter’s output, but the charger is not
allowed to charge.
Info:
To resume charging, access the Charger Standby menu and
press the CHANGE button.
Info:
If upon accessing this menu “
No AC In
” displays, you will not be
able to change the Charger’s status.
Bottom line shows
current charger status
This status will not change
until AC is connected
If a different status
is required:
press
press to change status
ON/OFF
CHANGE
MENU
HOME
CHARGER
Absorb
CHARGER
Status
CHARGER
Chg Stby
Possible statuses:
Absorb, Bulk, Charging, Equalizing (EQing), Float, Full Charge
(Full Chg), Load Support AAC (LS AAC), Load Support VDC (LS VDC)
Figure 3-11, Charger Standby Selections
3.2.11 Power On Menu
• POWER
ON
– Select whether to have the inverter power up and provide
AC power automatically once DC voltage is connected to it.
Default:
POWER ON = Norm
Range: Norm (Normal), Always
What is the Power On feature?
Normally, when DC power is connected
to the inverter, the user is required to press the power button—on the
inverter or remote—to turn the inverter on (
Norm
). When the Power On
feature is activated by selecting
Always
, the inverter is automatically turned
on and starts searching or inverting—depending on the
Search Watts
setting
(see Section 3.2.2). Once the inverter has connected to DC power and is
automatically turned on, the power button—on the inverter or remote—can
be used to turn the inverter on or off.
Why use the Power On feature?
Some customers are familiar with
Uninterruptible Power Supplies (UPS) that power-up automatically when DC
power is connected. The Power On feature can be used by customers that
want to obtain the same automatic power-up feature with which they are
familiar.