76
57-606 ECLIPSE Model 706 Guided Wave Radar Transmitter
3.6.6 Physical Specifications – Coaxial Probes
inches (mm)
Mounting
Flange
Optional
Flushing Port
3.38
(86)
4.18
(106)
3.77
(96)
45°
9.30
(236)
4.46
(113)
Probe
Insertion
Length
2 cable
entries
1/4" NPT
3.0 (76 mm)
typical
Model 7yT
with flanged connection
3.38
(86)
4.18
(106)
3.77
(96)
45°
9.30
(236)
2 cable
entries
7.76
(197)
Probe
Insertion
Length
Mounting
Flange
1/4" NPT
3.0 (76 mm)
typical
Optional
Flushing Port
Model 7yP
with flanged connection
3.38
(86)
4.18
(106)
3.77
(96)
45°
9.30
(236)
2 cable
entries
11.55
(293)
Probe
Insertion
Length
Mounting
Flange
Model 7yS
with flanged connection
3.38
(86)
4.18
(106)
3.77
(96)
45°
9.30
(236)
2 cable
entries
10.45
(265)
Probe
Insertion
Length
Mounting
Flange
1/4" NPT
3.0 (76 mm)
typical
Optional
Flushing Port
Model 7yD
with flanged connection
C
E
D
Coaxial Probe Slots
A
F
B
Coaxial GWR Probe,
End View
Dim.
Small Diameter
Enlarged (standard)
A
0.88 (22.5)
1.75 (45) - SST
1.92 (49) - HC and Monel
B
0.31 (8)
0.63 (16)
C
4.08 (100)
6.05 (153)
D
0.15 (4)
0.30 (8)
E
3.78 (96)
5.45 (138)
F
1.25 (32)
——