1.3 Safety information

Please read this operating manual carefully before operating the device and follow the instructions. Please keep this operating
manual accessible at all times. Damages to persons and property resulting from not complying with this operating manual are not
covered by the Product Liability Act. The manufacturer shall not be liable for any other damages resulting from not complying with
the instructions contained in this operating manual. Safety warnings warn against risks and help to prevent damage to persons
and property. Compliance with the safety warnings included in this operating manual is absolutely necessary to ensure personal
safety. Make sure that you comply with applicable national and international safety regulations. Each operator is personally respon-
sible for complying with the applicable regulations and must endeavour to comply with the most recent regulations.

1.4 Safety regulations

The magnetic

®

 Heating Water Regulator may only be operating by specialist personnel. Please comply with the manufacturer’s

instructions in the maintenance or replacement of consumable parts. The warranty shall be void if modifications are made to the
device. The manufacturer shall not be liable in the event of damage due to incorrect operation. In addition, this shall result in the
warranty becoming null and void. The regulator may not be operated in potentially explosive atmospheres, or underneath a naked
flame. The HWR plus may only be operated if it is in proper working condition and may only be used for the treatment of water in
closed heating and cooling circuits. The treatment of drinking water, acids, lyes, etc. is not permissable. Prior to operation, check
the system for possible damage. Ensure proper use within the stated performance range. Before carrying out repair work, it is
absolutely necessary to separate the system from the water pressure or supply network. Damaged systems should be decommis-
sioned immediately. Faulty or damaged reaction vessels should only be repaired by specialist personnel authorised by the manu-
facturer. This is in your own interest. This prevents inadequate repairs. Please pay attention to the relevant and binding standards.

1.5 Exclusion of liability

The use must be in exact accordance with the instructions provided in this manual. The manufacturer shall not be liable for 
any damage, including consequential damage resulting from the incorrect installation or incorrect use of this product.

1.6 Specific safety and handling instructions

The magnetic

®

 Heating Water Regulator is only suitable for water treatment for engineering applications.

The treated circulation water is not suitable for human consumption.
In order to prevent technical faults, it is necessary to rinse the regulator once a year using clear water, ideally with completely de-
mineralised water. In addition, in order to ensure ideal function, the high-potential magnesium anode installed in the device should
be replaced as a consumable at least every two years. If the Heating Water Regulator is operated using extremely hard water, then 
the increase of the pH value will result in lime scale along with the formation of lime sludge. In such a case, the reaction vessel 
should be cleaned twice a year. Heavy limescale on the interior walls of the vessel can be removed using a diluted natural acid, 
e.g. citric acid. The system is not resistant against strongly concentrated cleaning products.
The system may not be opened or disassembled during operation. The reaction vessel may not be opened without prior pressure
relief. The reaction container may contain hot water. Take appropriate precautions during maintenance work and protect yourself 
against burns due to high water temperatures. Protect the system against mechanical damage. Do not use near heat sources and 
naked flames. The installation of all parts should be carried out according to country-specific guidelines.

Summary of Contents for HWR 50 plus

Page 1: ...magnetic heating water regulator HWR 50 100 plus Operating manual magnetic einfach besser Anodenstrom...

Page 2: ...heim Tel 49 7944 94199 0 Fax 49 7944 94199 19 info magnetic online de www magnetic online de Managing director Shareholder Michael Bader VAT ID No DE 255 018 730 Trade Register HRA 571362 Registered c...

Page 3: ...operating instructions 1 8 Conformity declaration 2 Layout of the electrochemical water treatment 2 1 Layout of the Heating Water Regulator 2 2 Estimating the system volume 2 3 Water content of buffe...

Page 4: ...ring 7 Maintenance 7 1 Functional check flow rate 7 2 Functional check Anode function 7 3 Backwashing desludging container cleaning 7 4 Monitoring water quality 7 5 Anode replacement 8 Troubleshooting...

Page 5: ...l may be used for this purpose This operating manual must always be available at the place of operation 1 2 Area of application The magnetic Heating Water Regulator is used for the electrochemical tre...

Page 6: ...e system from the water pressure or supply network Damaged systems should be decommis sioned immediately Faulty or damaged reaction vessels should only be repaired by specialist personnel authorised b...

Page 7: ...to good engineering practice A leakage and original pressure inspection is carried out 2 Layout of the electrochemical water treatment 2 1 Layout of the Heating Water Regulator The magnetic Heating W...

Page 8: ...mp The advantage is that the treated water ends up directly in other system parts too Due to increasing the return flow temperature it is not suitable for condensing boiler techno logy System group re...

Page 9: ...low before buffer Installation in main return flow before the buffer tanks if oxygenation is likely or circulating impu rities are present Anodenstrom Anodenstrom Anodenstrom Notes on bypass installat...

Page 10: ...al residue Strongly contaminated old systems in particular those which have been pretreated using chemicals must be rinsed completely prior to installing an HWR For this purpose we recommend using our...

Page 11: ...lling water in conjunction with an HWR A residual conductivity of 50 100 S cm must be retained When using a heating water regulator the filling water should not be softened using ion exchange 4 4 Use...

Page 12: ...ntrol and document flow by means of the water metre provided 6 Success monitoring In order to guarantee the successful function of the regulator one should pay particular attention to the following po...

Page 13: ...up however ideally every 2 years checking and documenting water chemistry with regards to pH values and conductivity during maintenance and consulting us if the values strongly deviate from our recom...

Page 14: ...es mA on the display signalises how hard the HWR is working The display allows the following interpretations The display indicator is between 10 and 100 This is the normal operating range The lower th...

Page 15: ...he device After the rinse process close the ball valve 3 and fill the HWR with water 6 After rinsing is concluded lower the magnet on the chain again Open the ball valve 1 on the supply line to the HW...

Page 16: ...e layer is covering the anode which is preventing it from working Clean the anode with a wire brush then it should function again Otherwise check the display func tion using a 1 5V If it doesn t react...

Page 17: ...sulation the automatic quick bleeder is faulty In this case it needs to be replaced the water metre is not turning Check if the pumps are working and all the valves are open If the water metre is stil...