ReFlx 45 Collision Avoidance System Instruction Manual
September 2017
Page 5 of 17
DANGER, WARNING, CAUTION, and NOTE Statements
Read and understand this manual before installing, operating, or servicing this product. Install the product
according to this manual and local codes.
The following conventions indicate safety messages in this manual. Failure to heed these messages
could cause fatal injury or damage products and related equipment and systems.
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious
injury. This signal word is to be limited to the most extreme situations.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury
.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or
moderate injury. It may also be used to alert against unsafe practices.
NOTE: A NOTE statement is used to notify people of installation, operation, programming, or
maintenance information that is important, but not hazard-related.
Crane Safety
Collision Avoidance Unit
The sensor and reflector should never be disabled for any crane motion. If the unit is for any reason
disengaged or turned off the crane operating personnel must be notified immediately and proper alternate
operation precautions taken.
Operating the Crane with the ReFlx 45
The crane collision avoidance unit and limit switches, if any, should be checked at the beginning of each
shift or when a new operator takes control of the crane. When checking the collision avoidance unit and
limit switches the hoist should be centered over an area free of personnel and equipment.
The collision avoidance unit and limit switches should never be used as a regular, repetitive stopping
device. They are intended to be protective devices.
Cleaning Recommendations (Preventative Measures)
CAUTION
DO NOT WAIT FOR AN ACCIDENT TO OCCUR BEFORE PERFORMING PREVENTATIVE
MAINTENANCE. WIPE THE SENSOR AND REFLECTOR DOWN AT REGULAR INTERVALS TO
PREVENT DUST BUILD-UP THAT MAY INHIBIT THE SENSOR SIGNAL.