Magnetek Flex EM Manual Download Page 2

Your New Radio Remote

Thank you for your purchase of Magnetek’s Enrange

®

 brand Flex Radio Remote Equipment Control. 

Magnetek has set a whole new standard in radio-remote performance, dependability, and value with this 

unique new line of handheld transmitters. 

 

If your product ever needs modification or service, please contact one of our representatives at the 

following locations: 

 

U.S. Service Information 

 

For questions regarding service or technical information contact: 

1.866.MAG.SERV 

1.866.624.7378 

 

International Service: 

+1.262.783.3500 

 

Magnetek, Inc. 

N49 W13650 Campbell Drive  

Menomonee Falls, WI 53051 

 

Telephone:

 +1.800.288.8178 

Website:

 www.magnetek.com 

E-mail:

   

[email protected] 

 

Fax Numbers: 

Main:

    

+1.800.298.3503 

Sales:

    

+1.262.783.3510 

Service:

 +1.262.783.3508 

 

Canada Service Information: 

4090B Sladeview Crescent 

Mississauga, Ontario 

L5L 5Y5

 

Canada 

Phone: +1.800.792.7253 

Fax: +1.905.828.5707 

+1.416.424.7617 (24/7 Service pager) 

EU Market Contact: 

Brian Preston 

Magnetek (UK) Ltd. 

Unit 3 Bedford Business Centre, Mile Road 

Bedford, MK42 9TW UK 

Phone: +44.1234.349191 

Fax: +44.1234.268955 

 

©2014 MAGNETEK 

 

All rights reserved. This notice applies to all copyrighted materials included with this product, including, 

but not limited to, this manual and software embodied within the product. This manual is intended for the 

sole use of the person(s) to whom it was provided, and any unauthorized distribution of the manual or 

dispersal of its contents is strictly forbidden. This manual may not be reproduced in whole or in part by 

any means whatsoever without the expressed written permission of MAGNETEK. 

Summary of Contents for Flex EM

Page 1: ...Flex EM EX Transmitter Engineered Remote Equipment Control Part Number 191 00424 0001 R0 February 2014 2014 Magnetek Material Handling...

Page 2: ...Numbers Main 1 800 298 3503 Sales 1 262 783 3510 Service 1 262 783 3508 Canada Service Information 4090B Sladeview Crescent Mississauga Ontario L5L 5Y5 Canada Phone 1 800 792 7253 Fax 1 905 828 5707...

Page 3: ...3 GENERAL TRANSMITTER INFORMATION 10 3 1 EXTERNAL ILLUSTRATION 12 Button CONFIGURATION 10 3 2 INTERNAL ILLUSTRATION 12 Button CONFIGURATION 11 3 3 TYPES OF BUTTONS 11 4 DIP SWITCH SETTINGS 12 4 1 SYST...

Page 4: ...equipment where the radio system is used Plant safety rules and procedures of the employers and the owners of facilities where the Magnetek Products are being used Regulations issued by the Occupatio...

Page 5: ...intenance procedure practice etc which if not strictly observed could result in damage to or destruction of equipment or loss of functional effectiveness Cautions are highlighted as shown below CAUTIO...

Page 6: ...RE NOT DESIGNED TO INTERFACE DIRECTLY TO TWO STATE SAFETY CRITICAL MAINTAINED FUNCTIONS I E MAGNETS VACUUM LIFTS PUMPS EMERGENCY EQUIPMENT ETC A MECHANICALLY LOCKING INTERMEDIATE RELAY SYSTEM WITH SEP...

Page 7: ...izes the radio control Know how to keep the operator and other people clear of lifted loads and to avoid pinch points Continuously watch and monitor status of lifted loads Know and follow cable and ho...

Page 8: ...PRE OPERATION TEST At the start of each work shift or when a new operator takes control of the crane operators should do as a minimum the following steps before making lifts with any crane or hoist Te...

Page 9: ...a heating source 2 8 BATTERY CHARGING For those transmitters equipped with battery chargers please familiarize all users with the instructions of the charger before attempting to use Do not attempt t...

Page 10: ...Button 1 4 Push Button 3 5 Push Button 5 6 Push Button 7 7 Push Button 9 8 Push Button 11 9 Push Button 2 10 Push Button 4 11 Push Button 6 12 Push Button 8 13 Push Button 10 14 Push Button 12 15 Stra...

Page 11: ...EM or EX will differ slightly 3 3 TYPES OF BUTTONS Both the Flex EM and EX are offered in a number of button configurations They can be in four button eight button or twelve button configurations The...

Page 12: ...receiver must be set up to recognize the transmitter on its new channel Top slot 1 Bottom slot 0 Figure 5 The above dip switch setting 1 0 0 1 0 corresponds to channel 19 in the system channels table...

Page 13: ...d side of the transmitter handset and rotate it clockwise to the On position Figure 8 Figure 9 3 After turning on the transmitter power check the Status LED on the transmitter handset for any sign of...

Page 14: ...a period of inactivity push button not pressed defined by the dip switch the receiver E Stop will be disconnected and the unit must cycle power before turning on again 8 Turn off the transmitter powe...

Page 15: ...smitter The button that is active will be designated by the D C B A LEDs See Section 5 4 5 3 red blinks followed by a 2 second pause I CHIP error 6 4 red blinks followed by a 2 second pause Transmitti...

Page 16: ...nce Statement Part 15 19 This device complies with Part 15 of FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must acc...

Page 17: ...0 433 950MHZ 10011 05 433 200MHZ 00100 21 434 000MHZ 10100 06 433 250MHZ 00101 22 434 050MHZ 10101 07 433 300MHZ 00110 23 434 100MHZ 10110 08 433 350MHZ 00111 24 434 150MHZ 10111 09 433 400MHZ 01000 2...

Page 18: ...transmitter push button is pressed Improper startup settings Transmitter low battery power Check the transmitter battery level Emergency stop button activated prior to startup Prior to turning on the...

Page 19: ...Enrange Flex EM EX Instruction Manual February 2014 Page 19 of 19 8 NOTES...