4.2.4.2 Non-Interlocked Functions
Contrary to interlocked settings, non-interlocked settings allow the two adjacent push
buttons be used simultaneously. Non-interlocked settings are usually applied to a crane’s
auxiliary functions, such as lights, horn, 3
rd
speed and auxiliary stop. Each dip-switch on the
decoder module corresponds to one (1) motion or two (2) adjacent push buttons (left & right
push buttons).
Function
Code
Dip
Position
Setting
#1
Dip Position Setting
#2 - #4 (left button)
&
#5 - #7 (right button)
Function Description
A
1
000
Normal (momentary) contact.
B 1
001
Toggled
(latching)
contact.
C 1
011
Start function. For added safety,
you must first rotate and hold the power key
switch at “START” position and then press
the intended push button at the same
time to activate the output relay.
D 1
111
Auxiliary
Stop.
Example #1: Left button (set to function code A) / right button (set to function code A)
→
1
000 000
Example #2: Left button (set to function code B) / right button (set to function code B)
→
1
001 001
Example #3: Left button (set to function code A) / right button (set to function code C)
→
1
000 011
Example #4: Left button (set to function code C) / right button (set to function code B)
→
1 011 001